Contents
This section contains information about documentation content changes made to the SUSE Linux Enterprise Server Storage Administration Guide since the initial release of SUSE Linux Enterprise Server 11.
This document was updated on the following dates:
Updates were made to the following sections. The changes are explained below.
This section is new. Open Fibre Channel over Ethernet (OpenFCoE) is supported beginning in SLES 11.
This section is new.
This section is new.
|
Location |
Change | ||||
|---|---|---|---|---|---|
|
Section 7.4.5.5, “Configuring Default Multipath Behavior in /etc/multipath.conf” |
The default | ||||
|
In the dmsetup message commands, the 0 value represents the sector and is used when sector information is not needed. | |||||
|
Recommendations were added for the no_path_retry and failback settings when multipath I/O is used in a cluster environment. | |||||
|
The path-selector option names and settings were corrected:
|
|
Location |
Change |
|---|---|
|
This section is new. | |
|
Section 13.5.4, “iSCSI Targets Are Mounted When the Configuration File Is Set to Manual” |
This section is new. |
|
Location |
Change |
|---|---|
|
Section 5.1, “Guidelines for Resizing” Section 5.4, “Decreasing the Size of an Ext2 or Ext3 File System” |
The resize2fs command allows only the Ext3 file system to be resized if mounted. The size of an Ext3 volume can be increased or decreased when the volume is mounted or unmounted. The Ext2/4 file systems must be unmounted for increasing or decreasing the volume size. |
Updates were made to the following section. The changes are explained below.
|
Location |
Change |
|---|---|
|
Section 7.2.3, “Using LVM2 on Multipath Devices” Section 7.8, “Configuring Multipath I/O for an Existing Software RAID” |
Running mkinitrd is needed only if the root (/) device or any parts of it (such as |
Updates were made to the following section. The changes are explained below.
This release fixes broken links and removes obsolete references.
Updates were made to the following section. The changes are explained below.
Updates were made to the following sections. The changes are explained below.
|
Location |
Change |
|---|---|
|
The discussion and procedure were expanded to explain how to configure a partition that uses the entire disk. The procedure was modified to use the Hard Disk partitioning feature in the YaST Partitioner. | |
|
All LVM Management sections |
Procedures throughout the chapter were modified to use Volume Management in the YaST Partitioner. |
|
This section is new. | |
|
This section is new. | |
|
This section is new. | |
|
This section is new. |
Updates were made to the following sections. The changes are explained below.
|
Location |
Change |
|---|---|
|
Section 7.4.5.3, “Configuring User-Friendly Names or Alias Names in /etc/multipath.conf” |
Using user-friendly names for the root device can result in data loss. Added alternatives from TID 7001133: Recommendations for the usage of user_friendly_names in multipath configurations. |
|
Location |
Change |
|---|---|
|
Section 13.5.1, “Hotplug Doesn’t Work for Mounting iSCSI Targets” |
This section is new. |
Updates were made to the following sections. The changes are explained below.
|
Location |
Change |
|---|---|
|
The example in Step 3 was corrected. | |
|
Section 7.2.6, “SAN Timeout Settings When the Root Device Is Multipathed” |
This section is new. |
|
The file list for a package can vary for different server architectures. For a list of files included in the multipath-tools package, go to the Web page, find your architecture and select , then search on “multipath-tools” to find the package list for that architecture. | |
|
If the SAN device will be used as the root device on the server, modify the timeout settings for the device as described in Section 7.2.6, “SAN Timeout Settings When the Root Device Is Multipathed”. | |
|
Section 7.4.5.2, “Verifying the Setup in the etc/multipath.conf File” |
Added example output for -v3 verbosity. |
|
Section 7.7.1.1, “Enabling Multipath I/O at Install Time on an Active/Active Multipath Storage LUN” |
This section is new. |
|
Section 7.7.1.2, “Enabling Multipath I/O at Install Time on an Active/Passive Multipath Storage LUN” |
This section is new. |
|
Location |
Change |
|---|---|
|
Step 7.g in Section 13.2.2, “Creating iSCSI Targets with YaST” |
In the function, the option allows you to export the iSCSI target information, which makes it easier to provide this information to consumers of the resources. |
|
This section is new. |
|
Location |
Change |
|---|---|
|
The Software RAID HOW-TO has been deprecated. Use the Linux RAID wiki instead. |
Updates were made to the following sections. The changes are explained below.
|
Location |
Change |
|---|---|
|
Added information about using the | |
|
Section 7.10, “Scanning for New Partitioned Devices without Rebooting” |
Added information about using the |
Updates were made to the following sections. The changes are explained below.
|
Location |
Change |
|---|---|
|
Section 7.2.3, “Using LVM2 on Multipath Devices” Section 7.8, “Configuring Multipath I/O for an Existing Software RAID” |
The -f mpath option changed to -f multipath: mkinitrd -f multipath |
|
Multipath prio_callouts are located in shared libraries in |
|
Location |
Change |
|---|---|
|
Section 2.3.10, “Location Change for Multipath Tool Callouts” |
This section is new. |
|
Section 2.3.11, “Change from mpath to multipath for the mkinitrd -f Option” |
This section is new. |
Updates were made to the following sections. The changes are explained below.
|
Location |
Change |
|---|---|
|
Section 7.4.5.4, “Blacklisting Non-Multipathed Devices in /etc/multipath.conf” |
The keyword devnode_blacklist has been deprecated and replaced with the keyword blacklist. |
|
Section 7.4.5.5, “Configuring Default Multipath Behavior in /etc/multipath.conf” |
Changed getuid_callout to getuid. |
|
Section 7.6.2.1, “Understanding Priority Groups and Attributes” |
Changed getuid_callout to getuid. |
|
Added descriptions of least-pending, length-load-balancing, and service-time options. |
|
Location |
Change |
|---|---|
|
Section 2.3.9, “Advanced I/O Load-Balancing Options for Multipath” |
This section is new. |
Updates were made to the following section. The change is explained below.
Updates were made to the following sections. The changes are explained below.
|
Location |
Change |
|---|---|
|
Section 7.7, “Configuring Multipath I/O for the Root Device” |
Added Step 4 and Step 6 for System Z. |
|
Section 7.10, “Scanning for New Partitioned Devices without Rebooting” |
Corrected the syntax for the command lines in Step 2. |
|
Section 7.10, “Scanning for New Partitioned Devices without Rebooting” |
Step 7 replaces old Step 7 and Step 8. |
|
Location |
Change |
|---|---|
|
Section 13.3.1, “Using YaST for the iSCSI Initiator Configuration” |
Re-organized material for clarity. Added information about how to use the settings for the Start-up option for iSCSI target devices:
|
Updates were made to the following section. The changes are explained below.
|
Location |
Change |
|---|---|
|
Section 7.2.9.1, “Storage Arrays That Are Automatically Detected for Multipathing” |
Testing of the IBM zSeries device with multipathing has shown that the dev_loss_tmo parameter should be set to 90 seconds, and the fast_io_fail_tmo parameter should be set to 5 seconds. If you are using zSeries devices, you must manually create and configure the |
|
Multipathing is supported for the | |
|
Section 7.4.5.6, “Configuring Default Settings for zSeries in /etc/multipath.conf” |
This section is new. |
|
Section 7.7, “Configuring Multipath I/O for the Root Device” |