 SANESANE: Backends (Drivers)
The following table summarizes the backends/drivers distributed  with sane-backends-1.0.17, and the hardware or software they  support.
This is only a summary!
Please consult the manpages and the author-supplied webpages
for more detailed (and usually important) information
concerning each backend.
If you have new information or corrections, please file a
http://www.sane-project.org/bugs.htmlbug report with as many details as possible. Also please tell us if your scanner 
isn't mentioned in this list at all.
For an explanation of the tables, see the
#legendlegend .
There are tables for #SCANNERSscanners ,
#STILLstill cameras ,
#VIDEOvideo cameras ,
#APIAPIs , and
#METAmeta backends .
Scanners 
Backends: 
#S-ABATONabaton , 
#S-AGFAFOCUSagfafocus , 
#S-APPLEapple , 
#S-ARTECartec , 
#S-ARTEC-EPLUS48Uartec_eplus48u , 
#S-AS6Eas6e , 
#S-AVISIONavision , 
#S-BHbh , 
#S-CANONcanon , 
#S-CANON630Ucanon630u , 
#S-CANON-PPcanon_pp , 
#S-COOLSCANcoolscan , 
#S-COOLSCAN2coolscan2 , 
#S-EPSONepson , 
#S-FUJITSUfujitsu , 
#S-GENESYSgenesys , 
#S-GT68XXgt68xx , 
#S-HPhp , 
#S-HP4200hp4200 , 
#S-HP5400hp5400 , 
#S-HPSJ5Shpsj5s , 
#S-IBMibm , 
#S-LEOleo , 
#S-LEXMARKlexmark , 
#S-MA1509ma1509 , 
#S-MATSUSHITAmatsushita , 
#S-MICROTEKmicrotek , 
#S-MICROTEK2microtek2 , 
#S-MUSTEKmustek , 
#S-MUSTEK-PPmustek_pp , 
#S-MUSTEK-USBmustek_usb , 
#S-MUSTEK-USB2mustek_usb2 , 
#S-NECnec , 
#S-NIASHniash , 
#S-PIEpie , 
#S-PLUSTEKplustek , 
#S-PLUSTEK-PPplustek_pp , 
#S-RICOHricoh , 
#S-S9036s9036 , 
#S-SCEPTREsceptre , 
#S-SHARPsharp , 
#S-SM3600sm3600 , 
#S-SM3840sm3840 , 
#S-SNAPSCANSnapScan , 
#S-SP15Csp15c , 
#S-ST400st400 , 
#S-TAMARACKtamarack , 
#S-TECO1teco1 , 
#S-TECO2teco2 , 
#S-TECO3teco3 , 
#S-U12u12 , 
#S-UMAXumax , 
#S-UMAX1220Uumax1220u , 
#S-UMAX-PPumax_pp , 
#S-UNSUPPORTEDunsupported 
Backend: abaton
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-abaton.5.htmlsane-abaton 
ManufacturerModelInterfaceStatusComment Abaton
Scan 300/GS SCSI complete All known modes and functions supported Scan 300/S SCSI untested Untested, use with caution Backend: agfafocus
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-agfafocus.5.htmlsane-agfafocus 
ManufacturerModelInterfaceStatusComment http://www.agfa.com/AGFA Focus GS Scanner SCSI untested 6 bit gray Focus Lineart Scanner SCSI untested Lineart only? Untested. Focus II SCSI untested gray only Focus Color SCSI good 3-pass Focus Color Plus SCSI good 3-pass Siemens
S9036 SCSI untested gray only Backend: apple
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-apple.5.htmlsane-apple 
ManufacturerModelInterfaceStatusComment http://developer.apple.com/Apple Apple Scanner SCSI good 4bit, 16 shades of gray OneScanner SCSI basic 8bit, 256 shades of gray. The backend needs work especially in the quantization code but it may work. ColorOneScanner SCSI minimal truecolor (needs much work) but it scans in non color modes. Backend: artec
(unmaintained)
Link(s): 
http://www4.infi.net/~cpinkham/sane/sane-artec-doc.htmlhttp://www4.infi.net/~cpinkham/sane/sane-artec-doc.html Manual page: http://www.sane-project.org/man/sane-artec.5.htmlsane-artec 
ManufacturerModelInterfaceStatusComment http://www.artecusa.com/Artec/Ultima AT3 SCSI complete all modes working A6000C SCSI complete all modes working A6000C PLUS SCSI complete f/w = v1.93 OK AT6 SCSI minimal First scan works, subsequent fail until scanner power cycle. AT12 SCSI complete all modes working AM12S SCSI complete all modes working http://www.blackwidow.co.uk/BlackWidow BW4800SP SCSI complete rebadged Artec AT3 http://www.plustek.com/Plustek OpticPro 19200S SCSI complete rebadged Artec AM12S Backend: artec_eplus48u
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-artec_eplus48u.5.htmlsane-artec_eplus48u 
ManufacturerModelInterfaceStatusComment http://www.artecusa.com/Artec/Ultima E+ 48U USB good CIS scanner based on the GT6816 chip. Apparently all other devices are re-badged Artec scanners. http://www.medion.comMedion/Lifetec/Tevion/Cytron MD9693 USB good  MD9705 USB good  MD4394 USB good Only scanners with product id 0x4003 will work; try the gt68xx backend, if your scanner has product id 0x4002 http://www.trust-site.comTrust Easy Webscan 19200 USB good Different product id: 0x4006 240H Easy Webscan Gold USB basic Different product id: 0x4007, works up to 600 dpi http://www.artecusa.com/Memorex MEM 48U USB good Different product id: 0x4005 http://www.microstar.de/Microstar MR 9791 USB good  http://www.umax.com/UMAX AstraSlim SE USB good Different product id: 0x4009 AstraSlim 1200 SE USB good Different product id: 0x4010 http://www.artecusa.com/Artec/Ultima E+ Pro USB minimal Experimental! Different product id: 0x4004. Please report your results! Backend: as6e
(0.4.2)
Link(s): 
http://as6edriver.sourceforge.net/http://as6edriver.sourceforge.net/ Manual page: http://www.sane-project.org/man/sane-as6e.5.htmlsane-as6e 
ManufacturerModelInterfaceStatusComment http://www.artecusa.com/Artec/Ultima AS6E Parport basic Requires the program 'as6edriver' to run. http://www.trust-site.comTrust Easy Scan 9600 Plus Parport basic Requires the program 'as6edriver' to run. Backend: avision
(Build: 167)
Link(s): 
http://www.exactcode.de/oss/avision/index.htmlhttp://www.exactcode.de/oss/avision/index.html Manual page: http://www.sane-project.org/man/sane-avision.5.htmlsane-avision 
ManufacturerModelInterfaceStatusComment http://www.avision.comAvision AV100CS SCSI untested  AV100IIICS SCSI untested  AV100S SCSI untested  AV120 USB basic sheetfed scanner AV210 USB basic sheetfed scanner AV210-2 USB basic sheetfed scanner AV220 USB complete duplex! sheetfed scanner AV220-C2 USB untested duplex! sheetfed scanner AV240SC SCSI untested  AV260CS SCSI untested  AV360CS SCSI untested  AV363CS SCSI untested  AV420CS SCSI untested  AV6120 SCSI untested  AV610 USB good  AVA6 USB untested probably a CPU-less device DS610CU Scancopier USB good 1 pass, 600 dpi, A4 AV620CS SCSI complete 1 pass, 600 dpi AV620CS Plus SCSI complete 1 pass, 1200 dpi AV630CS SCSI complete 1 pass, 1200 dpi - regularly tested AV630CSL SCSI untested 1 pass, 1200 dpi AV6240 SCSI complete 1 pass, ??? dpi AV600U USB good 1 pass, 600 dpi AV600U Plus USB untested 1 pass, ??? dpi AV660S SCSI untested 1 pass, ??? dpi AV680S SCSI untested 1 pass, ??? dpi AV690U SCSI untested 1 pass, 2400 dpi AV800S SCSI untested 1 pass, ??? dpi AV810C SCSI untested 1 pass, ??? dpi AV820 SCSI untested 1 pass, ??? dpi AV820C SCSI good 1 pass, ??? dpi AV820C Plus SCSI untested 1 pass, ??? dpi AV830C SCSI untested 1 pass, ??? dpi AV830C Plus SCSI untested 1 pass, ??? dpi AV880 SCSI untested 1 pass, ??? dpi AV880C SCSI untested 1 pass, ??? dpi AV3200C SCSI complete 1 pass, ??? dpi AV3800C SCSI good 1 pass, ??? dpi AV8000S SCSI complete 1 pass, 1200 dpi, A3 - regularly tested AV8300 USB complete 1 pass, 1200 dpi, A3 - duplex! AV8350 USB complete 1 pass, 1200 dpi, A3 - duplex! AVA3 SCSI basic 1 pass, 600 dpi, A3 http://www.hp.comHewlett-Packard ScanJet 5300C USB complete 1 pass, 2400 dpi - regularly tested - some FW revisions have x-axis image scaling problems over 1200 dpi ScanJet 5370C USB basic 1 pass, 2400 dpi - some FW revisions have x-axis image scaling problems over 1200 dpi ScanJet 7400c USB good 1 pass, 2400 dpi - dual USB/SCSI interface ScanJet 7450c USB good 1 pass, 2400 dpi - dual USB/SCSI interface - regularly tested ScanJet 7490c USB good 1 pass, 1200 dpi - dual USB/SCSI interface ScanJet 8200 USB good 1 pass, 4800 (?) dpi - USB 2.0 ScanJet 8250 USB good 1 pass, 4800 (?) dpi - USB 2.0 ScanJet 8290 USB good 1 pass, 4800 (?) dpi - USB 2.0 and SCSI - only SCSI tested so far http://www.minolta.comMinolta Dimage Scan Dual I SCSI basic  Dimage Scan Dual II USB good 1 pass, film-scanner Elite II USB untested 1 pass, film-scanner Dimage Scan Dual III USB basic 1 pass, film-scanner Minolta-QMS
SC-110 USB untested  SC-215 USB good  Mitsubishi
MCA-ADFC SCSI untested  S1200C SCSI untested  S600C SCSI untested  SS600 SCSI good  http://www.fujitsu.comFujitsu ScanPartner SCSI untested  ScanPartner 10 SCSI untested  ScanPartner 10C SCSI untested  ScanPartner 15C SCSI untested  ScanPartner 300C SCSI untested  ScanPartner 600C SCSI untested  ScanPartner 620C SCSI good  ScanPartner Jr SCSI untested  ScanStation SCSI untested  http://www.kodak.comKodak i30 SCSI untested  i40 SCSI untested  i50 SCSI untested  i60 SCSI untested  i80 SCSI untested  iVina
1200U USB untested  Xerox
DocuMate252 USB untested  DocuMate262 USB untested  Backend: bh
(1.0-4)
Link(s): 
http://www.martoneconsulting.com/sane-bh.htmlhttp://www.martoneconsulting.com/sane-bh.html Manual page: http://www.sane-project.org/man/sane-bh.5.htmlsane-bh Comment: Supports Copiscan II scanners with Remote SCSI Controller (RSC) interface
ManufacturerModelInterfaceStatusComment http://www.bhscanners.com/Bell and Howell COPISCAN II 6338 SCSI good Duplex Scanner with ACE - development model COPISCAN II 2135 SCSI untested Simplex Scanner COPISCAN II 2137(A) SCSI good Simplex Scanner (with ACE) - limited testing COPISCAN II 2138A SCSI untested Simplex Scanner with ACE COPISCAN II 3238 SCSI untested Simplex Scanner COPISCAN II 3338(A) SCSI untested Simplex Scanner (with ACE) Backend: canon
(1.12)
Link(s): 
http://www.rzg.mpg.de/~mpd/sane/http://www.rzg.mpg.de/~mpd/sane/ Manual page: http://www.sane-project.org/man/sane-canon.5.htmlsane-canon 
ManufacturerModelInterfaceStatusComment http://www.canon.com/Canon CanoScan 300 SCSI good 1 pass; flatbed scanner CanoScan 600 SCSI good 1 pass; flatbed scanner CanoScan 620S SCSI good 1 pass; flatbed scanner CanoScan 1200S SCSI good 1 pass; flatbed scanner CanoScan 2700F SCSI good 1 pass; film scanner CanoScan 2710S SCSI good 1 pass; 36bit film scanner Backend: canon630u
(0.1)
Link(s): 
http://canon-fb630u.sourceforge.net/http://canon-fb630u.sourceforge.net/ Manual page: http://www.sane-project.org/man/sane-canon630u.5.htmlsane-canon630u 
ManufacturerModelInterfaceStatusComment http://www.canon.com/Canon CanoScan fb630u USB good OK CanoScan fb636u USB good OK Backend: canon_pp
(0.33)
Link(s): 
http://canon-fb330p.sourceforge.nethttp://canon-fb330p.sourceforge.net Manual page: http://www.sane-project.org/man/sane-canon_pp.5.htmlsane-canon_pp 
ManufacturerModelInterfaceStatusComment http://www.canon.com/Canon CanoScan FB310P Parport (ECP) unsupported Rebadged Avision, different command set CanoScan FB610P Parport (ECP) unsupported Rebadged Avision, different command set CanoScan FB320P Parport (ECP) basic Newly added support CanoScan FB620P Parport (ECP) basic Newly added support CanoScan FB330P Parport (ECP) good  CanoScan FB630P Parport (ECP) good  CanoScan N340P Parport (ECP) good  CanoScan N640P Parport (ECP) good  CanoScan N640P ex Parport (ECP) good Just an N640P in a different box? Backend: coolscan
(0.4.3)
Link(s): 
http://andreas.rick.free.fr/sane/http://andreas.rick.free.fr/sane/ Manual page: http://www.sane-project.org/man/sane-coolscan.5.htmlsane-coolscan 
ManufacturerModelInterfaceStatusComment http://www.nikon.com/Nikon LS-20 SCSI basic The LS-20 has been replaced by the LS-30 LS-30 SCSI basic alpha: only 24/30 bit RGB + 32/40 bit RGBI LS-2000 SCSI basic alpha: only 24/36 bit + RGB 32/48 bit RGBI LS-1000 SCSI basic Doesn't support gamma correction Backend: coolscan2
(0.1.8)
Link(s): 
http://coolscan2.sourceforge.net/http://coolscan2.sourceforge.net/ Manual page: http://www.sane-project.org/man/sane-coolscan2.5.htmlsane-coolscan2 
ManufacturerModelInterfaceStatusComment http://www.nikon.com/Nikon LS 30 SCSI complete working -- model available to developer LS 2000 SCSI good  LS 40 ED USB complete  LS 4000 ED IEEE-1394 good needs linux kernel 2.4.19 or later LS 8000 ED IEEE-1394 good needs linux kernel 2.4.19 or later Backend: epson
(0.2.42)
Link(s): 
http://www.khk.net/sanehttp://www.khk.net/sane Manual page: http://www.sane-project.org/man/sane-epson.5.htmlsane-epson 
ManufacturerModelInterfaceStatusComment http://www.epson.com/Epson GT-5000 SCSI Parport good  Actionscanner II SCSI Parport good US version of GT-5000 GT-6000 SCSI Parport good  ES-300C SCSI Parport good US version of GT-6000 ES-300GS SCSI good  GT-5500 SCSI good  GT-6500 Parport good  ES-600C Parport good US version of GT-6500 ES-1200C Parport good US version of GT-9000 GT-7000 SCSI good  GT-8000 SCSI good  ES-8500 SCSI good  Perfection 636S SCSI complete US version of GT-7000 Perfection 636U USB complete  Perfection 610 USB complete  Perfection 640 USB complete  Perfection 1200S SCSI complete  Perfection 1200U USB complete  Perfection 1200Photo USB complete with TPU Perfection 1240 SCSI USB complete  Perfection 1640 SCSI USB complete  Perfection 1650 USB complete  Perfection 1660 USB complete  Perfection 2400 USB complete  Perfection 2450 USB IEEE-1394 complete  Perfection 3200 USB complete US version of the GT-9800 Perfection 4870 USB complete US version of the GT-9800 Expression 636 SCSI complete US version of GT-9500 Expression 800 SCSI complete  Expression 1600 SCSI USB IEEE-1394 complete  Expression 1680 SCSI USB IEEE-1394 complete  http://www.vjet.demon.co.uk/scanner/FilmScan 200 SCSI unsupported A better backend for the FilmScan 200 can be found at http://www.vjet.demon.co.uk/scanner/ http://www.vjet.demon.co.uk/scanner/ CX-3200 USB good  CX-3600 USB good  CX-3650 USB good  CX-4600 USB good  CX-5200 USB good  CX-5400 USB good  CX-6400 USB good  RX-500 USB good  RX-600 USB good  RX-425 USB good  DX-3850 USB good  CX-3700 USB good  CX-3800 USB good  DX-3800 USB good  CX-4200 USB good  AcuLaser CX11 USB good  AcuLaser CX11NF USB good  CX-6600 USB good  Backend: fujitsu
(1.12)
Manual page: http://www.sane-project.org/man/sane-fujitsu.5.htmlsane-fujitsu 
ManufacturerModelInterfaceStatusComment http://www.fujitsu.com/services/computing/peripheral/scanners/product/Fujitsu M3096G SCSI good  http://www.remote.org/frederik/projects/software/sane/M3091DCd SCSI good  M3092DCd SCSI good  M3093GXim SCSI good  M3093GDim SCSI good  M4097 SCSI good  ScanPartner 93GX SCSI good  fi-4120C SCSI USB basic  fi-4220C SCSI USB basic  fi-4340C SCSI basic Color scans are inverted, Flatbed option is enabled fi-4530C SCSI USB basic USB untested Backend: genesys
(1.0-8)
Link(s): 
http://www.meier-geinitz.de/sane/genesys-backend/http://www.meier-geinitz.de/sane/genesys-backend/ Manual page: http://www.sane-project.org/man/sane-genesys.5.htmlsane-genesys Comment: Only the USB scanners mentioned below are currently supported.
ManufacturerModelInterfaceStatusComment http://www.medion.com/Medion/Lifetec/Tevion/Cytron MD5345 USB good Has a Primax USB ID MD6228 USB good Has a Primax USB ID. Same as MD5345 MD6471 USB complete Has a Primax USB ID. Same as MD5345 http://www.hp.com/Hewlett-Packard ScanJet 2300C USB complete 600x1200 dpi max http://www.canon.com/Canon CanoScan LiDE 35 USB good Same ids as LiDE 50. CanoScan LiDE 40 USB untested Same ids as LiDE 50. Please tell us if this scanner works. CanoScan LiDE 50 USB good  CanoScan LiDE 60 USB good  Backend: gt68xx
(1.0-79)
Link(s): 
http://www.meier-geinitz.de/sane/gt68xx-backend/http://www.meier-geinitz.de/sane/gt68xx-backend/ Manual page: http://www.sane-project.org/man/sane-gt68xx.5.htmlsane-gt68xx Comment: Only the USB scanners mentioned below are supported. For other Mustek BearPaws, look at the Plustek and the MA-1509 backend.
ManufacturerModelInterfaceStatusComment http://www.artecusa.com/Artec/Ultima Ultima 2000 USB good Works, only product id 0x4002 is supported Ultima 2000 e+ USB good Works, only limited testing until now Boeder
Sm@rtScan Slim Edition USB good Similar to Artec Ultima 2000 http://www.fujitsu.com/Fujitsu 1200CUS USB basic Works, but is slow. Probably a Mustek BearPaw 2400 CU clone. http://www.genius-kye.com/Genius Colorpage Vivid3x USB good  Colorpage Vivid3 V2 USB good Same as Colorpage Vivid3x Colorpage Vivid3xe USB good  Colorpage Vivid4 USB good  Colorpage Vivid4x USB good  Colorpage Vivid4xe USB good  Colorpage Vivid 1200 X USB good  Colorpage Vivid 1200 XE USB good  Googlegear
2000 USB good Same as Artec Ultima 2000. http://www.lexmark.com/Lexmark X70 USB good Works, some resolutions fail at 16 bit X73 USB good Works, some resolutions fail at 16 bit, same as X70 http://www.medion.comMedion/Lifetec/Tevion/Cytron MD 4394 USB good Product id 0x4002. If you have 0x4003, use artec_eplus48u backend. MD/LT 9375 USB untested Untested, but is reported to have the same ids as the Artec Ultima 2000. Please test. MD/LT 9385 USB good Similar to Artec Ultima 2000 LT 9452 USB good Similar to Mustek ScanExpress 1200 UB Plus MD 9458 USB good Similar to Artec Ultima 2000 (e+?) http://www.mustek.com/Mustek BearPaw 1200 CS USB good  BearPaw 1200 CU USB good  BearPaw 1200 CU Plus USB good  BearPaw 1200 TA USB good Transparency adapter supported BearPaw 2400 CS USB untested Probably works, reports are welcome BearPaw 2400 CS Plus USB good Works, problems with 12/16 bit modes? BearPaw 2400 CU USB basic Works, but is slow BearPaw 2400 CU Plus USB good  BearPaw 2400 TA USB good Transparency adapter supported BearPaw 2400 TA Plus USB good Transparency adapter supported BearPaw 2448 CS Plus USB basic Slow. Same as 2448 TA Plus, but without TA. BearPaw 2448 TA Plus USB basic Slow. Transparency adapter supported. Slow. Brightness depends on resolution? Plug-n-Scan 2400 MT USB good Works but is slow in high resolutions. Same as BearPaw 2400 TA Plus. Plug-n-Scan 2400 M USB good Works but is slow in high resolutions. Same as BearPaw 2400 CS Plus. ScanExpress 1200 UB Plus USB good  ScanExpress 1248 UB USB complete  ScanExpress A3 USB USB basic Still some vertical stripes. ScanExpress 2400 USB USB minimal Should be detected but may need some more work in the code. Testers welcome. Please contact me if you own this scanner. ScanMagic 1200 UB Plus USB good Same as ScanExpress 1200 UB Plus Packard Bell
Diamond 1200 USB good Similar to Mustek BearPaw 1200 (Plus) Diamond 1200 Plus USB good Similar to Mustek BearPaw 1200 Plus Diamond 2450 USB good  http://www.plustek.de/Plustek OpticPro 1248U USB good  OpticPro U16B USB good  OpticPro U16B+ USB good  OpticPro UT16B USB untested Probably works. Transparency adapter not supported yet. Please contact me if you own such a device. OpticSlim 1200 USB good  OpticSlim 2400 USB good Works up to 1200 dpi. OpticSlim M12 USB basic Scans, but no calibration is performed and the area selection is limited. RevScan
19200i USB good Similar to Plustek OpticPro 1248U http://www.trust-site.comTrust Flat Scan USB 19200 USB good Similar to Artec Ultima 2000 Compact Scan USB 19200 USB good Works, if you have vendor id 0x055f and product id 0x0006, use the mustek_usb backend instead, similar to Mustek ScanExpress 1200 UB (Plus) 240TH Easy Webscan Gold USB good Same as Mustek Bearpaw 2400 TA plus. Direct WebScan 19200 USB good Same as Mustek BearPaw 1200 CU Plus (0x021c). http://www.visioneer.com/Visioneer OneTouch 7300 USB good Works upto 1200 dpi and 12 bits/color. Backend: hp
(1.06)
Link(s): 
http://www.kirchgessner.net/http://www.kirchgessner.net/ Manual page: http://www.sane-project.org/man/sane-hp.5.htmlsane-hp 
ManufacturerModelInterfaceStatusComment http://www.hp.com/Hewlett-Packard ScanJet Plus Propietary complete Driver for HP parallel interface card required ScanJet IIc SCSI complete  ScanJet IIp SCSI complete  ScanJet IIcx SCSI complete  ScanJet 3c SCSI complete  ScanJet 3p SCSI complete  ScanJet 4c SCSI complete  ScanJet 4p SCSI complete  ScanJet 4100C USB complete  ScanJet 5p SCSI complete  ScanJet 5100C Parport complete Requires ppscsi driver and epst module ScanJet 5200C Parport USB complete Parallel interface requires ppscsi driver and epst module ScanJet 6100C SCSI complete  ScanJet 6200C SCSI USB complete  ScanJet 6250C SCSI USB complete  ScanJet 6300C SCSI USB complete  ScanJet 6350C SCSI USB complete  ScanJet 6390C SCSI USB complete  PhotoSmart PhotoScanner SCSI complete  Backend: hp4200
(1.0-2, 
NEW!)
Link(s): 
http://hp4200-backend.sourceforge.nethttp://hp4200-backend.sourceforge.net Manual page: http://www.sane-project.org/man/sane-hp4200.5.htmlsane-hp4200 
ManufacturerModelInterfaceStatusComment http://www.hp.com/Hewlett-Packard ScanJet 4200C USB basic 8bpp color, 75/150/300/600 dpi only ScanJet 4200Cxi USB basic 8bpp color, 75/150/300/600 dpi only ScanJet 4200Cse USB basic 8bpp color, 75/150/300/600 dpi only Backend: hp5400
(1.0-2)
Link(s): 
http://sourceforge.net/projects/hp5400backendhttp://sourceforge.net/projects/hp5400backend Manual page: http://www.sane-project.org/man/sane-hp5400.5.htmlsane-hp5400 Comment: HP5400 and HP5470 scanners. Prototype backend available
ManufacturerModelInterfaceStatusComment http://www.hp.comHewlett-Packard ScanJet 5400c USB basic  ScanJet 5470c USB basic  ScanJet 5490c USB basic  Backend: hpsj5s
(0.03)
Link(s): 
http://hpsj5s.sourceforge.net/http://hpsj5s.sourceforge.net/ Manual page: http://www.sane-project.org/man/sane-hpsj5s.5.htmlsane-hpsj5s 
ManufacturerModelInterfaceStatusComment http://www.hp.com/Hewlett-Packard ScanJet 5s Parport (EPP) minimal Requires libieee1284 library. Only gray mode. Backend: ibm
(1.0-4)
Link(s): 
http://www.meier-geinitz.de/sane/ibm-backend/http://www.meier-geinitz.de/sane/ibm-backend/ Manual page: http://www.sane-project.org/man/sane-ibm.5.htmlsane-ibm Comment: This backend has had only limited testing. It needs more work especially for the Ricoh scanners. Patches are welcome.
ManufacturerModelInterfaceStatusComment http://www.ibm.com/IBM 2456 SCSI basic Was reported to work long time ago. Reports are welcome. Ricoh
IS-410 SCSI untested Untested, please report! IS-420 SCSI basic Works at least in flatbed mode. IS-430 SCSI untested Untested, please report! Backend: leo
(1.0-10)
Link(s): 
http://www.zago.net/sane/#leohttp://www.zago.net/sane/#leo Manual page: http://www.sane-project.org/man/sane-leo.5.htmlsane-leo 
ManufacturerModelInterfaceStatusComment LEO
LEOScan S3 SCSI good FCC ID LUZFS1130 Across Technologies
FS-1130 SCSI good FCC ID LUZFS1130 Genius
FS-1130 Colorpage Scanner SCSI good  Backend: lexmark
(1.0-0, 
NEW!)
Link(s): 
http://ca.geocities.com/freshshelf@rogers.com/http://ca.geocities.com/freshshelf@rogers.com/ Manual page: http://www.sane-project.org/man/lexmark.5.htmllexmark Comment: This backend supports lexmark x1100 series scanners.
ManufacturerModelInterfaceStatusComment http://www.lexmark.com/Lexmark X1110 USB untested  /unsupported/lexmark-x1150.htmlX1130 USB untested  X1140 USB untested  /unsupported/lexmark-x1150.htmlX1150 USB untested  X1170 USB untested  /unsupported/lexmark-x1150.htmlX1180 USB basic  X1185 USB basic Tested with xscanimage. Supports 75, 150, 300, 600, 1200(600x1200) dpi resolutions. Does grayscale or colour scans in the following sizes: wallet, 3x5, 4x6, 5x7, 8x10, letter. Backend: ma1509
(1.0-3)
Link(s): 
http://www.meier-geinitz.de/sane/ma1509-backend/http://www.meier-geinitz.de/sane/ma1509-backend/ Manual page: http://www.sane-project.org/man/sane-ma1509.5.htmlsane-ma1509 
ManufacturerModelInterfaceStatusComment http://www.mustek.com/Mustek BearPaw 1200 F USB good Works upto 600 dpi. No support for TA and ADF yet. Fujitsu
fi-4110EOX2 USB unsupported Uses ma1509 chip, but very different from other scanners supported by backend Backend: matsushita
(1.0-7)
Link(s): 
http://www.zago.net/sanehttp://www.zago.net/sane Manual page: http://www.sane-project.org/man/sane-matsushita.5.htmlsane-matsushita 
ManufacturerModelInterfaceStatusComment http://www.panasonic.com/Panasonic KV-SS25 SCSI complete  KV-SS25D SCSI complete  KV-SS50 SCSI untested  KV-SS55 SCSI untested  KV-SS50EX SCSI untested  KV-SS55EX SCSI minimal no color, no high resolution, no automatic cropping KV-SS850 SCSI untested  KV-SS855 SCSI untested  KV-S2025C SCSI minimal no color, no high resolution, no automatic cropping KV-S2045C SCSI minimal no color, no high resolution, no automatic cropping KV-S2065L SCSI minimal no color, no high resolution, no automatic cropping Backend: microtek
(0.13.1)
Link(s): 
http://www.mir.com/mtek/http://www.mir.com/mtek/ Manual page: http://www.sane-project.org/man/sane-microtek.5.htmlsane-microtek 
ManufacturerModelInterfaceStatusComment http://www.microtek.com/Microtek Scanmaker E6 SCSI good  Scanmaker E3 SCSI good  Scanmaker E2 SCSI good 3-pass Scanmaker 35t+ SCSI good slide-scanner Scanmaker 45t SCSI good slide-scanner Scanmaker 35 SCSI good slide-scanner Scanmaker III SCSI good  Scanmaker IISP SCSI good  Scanmaker IIHR SCSI good 3-pass Scanmaker IIG SCSI good gray only Scanmaker II SCSI good 3-pass Scanmaker 600Z(S) SCSI untested  Scanmaker 600G(S) SCSI basic gray only (see manpage) Color PageWiz SCSI (Parport) basic sheet-fed (preliminary, see mapage) http://www.agfa.com/Agfa Arcus II SCSI good Arcus *II*, not Arcus! StudioScan SCSI good  StudioScan II SCSI good  StudioScan IIsi SCSI good  Studiostar SCSI minimal Is detected but scans are very dark DuoScan SCSI basic  http://www.vobis.de/Vobis Highscreen Realscan SCSI good  http://www.genius-kye.com/Genius Colorpage-SP2 SCSI good Same as Microtek Scanmaker E3 Backend: microtek2
(unmaintained)
Link(s): 
http://karstenfestag.gmxhome.de/linux.htmlhttp://karstenfestag.gmxhome.de/linux.html Manual page: http://www.sane-project.org/man/sane-microtek2.5.htmlsane-microtek2 
ManufacturerModelInterfaceStatusComment http://www.microtek.com/Microtek ScanMaker E3plus Parport complete  ScanMaker E3plus SCSI complete  ScanMaker X6 SCSI complete  ScanMaker X6EL SCSI basic  ScanMaker X6USB USB good  ScanMaker V300 SCSI good  ScanMaker V300 Parport good  ScanMaker V310 SCSI basic  ScanMaker V310 Parport basic  ScanMaker V600 SCSI basic  ScanMaker V600 Parport basic  ScanMaker 330 SCSI basic  ScanMaker 630 SCSI basic  ScanMaker 636 SCSI complete  ScanMaker 9600XL SCSI good only flatbed mode ? /unsupported/microtek-scanmaker-9800.htmlScanMaker 9800XL IEEE-1394 minimal IEEE-1394 seems to work. See link. More reports welcome. Phantom 330CX Parport complete  SlimScan C3 Parport complete  Phantom 636 SCSI complete  Phantom 636CX Parport complete  SlimScan C6 USB complete  ScanMaker V6UPL USB basic Sometimes scan speed goes to fast and results look badly smudged. ScanMaker V6USL SCSI complete  ScanMaker V6USL USB complete  ScanMaker X12USL SCSI good only Flatbed mode ? http://www.vobis.de/Vobis HighScan SCSI complete only E3plus based models http://www.scanport.com/Scanport SQ300 Parport? basic  SQ2030 Parport basic  SQ4836 SCSI basic  http://www.geniusmouse.co.uk/Genius ColorPage-EP Parport good  Backend: mustek
(1.0-138)
Link(s): 
http://www.meier-geinitz.de/sane/mustek-backend/http://www.meier-geinitz.de/sane/mustek-backend/ Manual page: http://www.sane-project.org/man/sane-mustek.5.htmlsane-mustek Comment: Most Mustek SCSI scanners are supported by this backend. For USB scanners, look at the mustek_usb backend.
ManufacturerModelInterfaceStatusComment http://www.mustek.com/Mustek Paragon MFS-6000CX SCSI good 3-pass Paragon MFS-12000CX SCSI good 3-pass Paragon MFC-600S SCSI complete  Paragon 600 II CD SCSI complete  Paragon 600 II ED Parport untested Completely untested. If it's the same as the 600 II EP, it may work. Please contact me if you own such a device. Paragon 600 II EP Parport minimal Works, however only low resolutions and quality in color mode is bad. ScanMagic 600 II SP SCSI complete  TwainScan II SP SCSI complete  Paragon MFC-800S SCSI complete  Paragon 800 II SP SCSI complete  Paragon MFS-6000SP SCSI complete  Paragon MFS-8000SP SCSI complete  Paragon MFS-1200SP SCSI complete  Paragon MFS-12000SP SCSI complete  ScanExpress 6000SP SCSI complete  ScanExpress 12000SP SCSI complete  ScanExpress 1200 FS SCSI untested One report that it crashes the computer. SCSI driver issue? Please contact me if you own such a device. ScanExpress 12000SP Plus SCSI complete  Paragon 1200 III SP SCSI complete  Paragon 1200 LS SCSI complete  ScanMagic 9636S SCSI complete  ScanMagic 9636S Plus SCSI complete  ScanExpress A3 SP SCSI basic Please test! Paragon 1200 SP Pro SCSI good  Paragon 1200 A3 Pro SCSI complete ADF and TA untested. Please contact me if you own such equipment. Paragon 600 II N Proprietary basic Resolutions above 300 dpi may cause trouble. http://www.trust-site.comTrust Imagery 1200 SCSI good 3-pass, Mustek Paragon MFS-6000CX compatible Imagery 1200 SP SCSI complete Mustek Paragon MFS-6000SP compatible Imagery 4800 SP SCSI complete Mustek Paragon 600 II CD compatible SCSI Connect 19200 SCSI complete Mustek ScanExpress 12000SP compatible SCSI excellence series 19200 SCSI complete Mustek ScanExpress 12000SP compatible http://www.primax.nl/Primax Compact 4800 SCSI SCSI complete Mustek 600 II CD compatible Backend: mustek_pp
(13)
Link(s): 
http://penguin-breeder.org/sane/mustek_pp/http://penguin-breeder.org/sane/mustek_pp/ Manual page: http://www.sane-project.org/man/sane-mustek_pp.5.htmlsane-mustek_pp Comment: Supports CIS and CCD type parallel port scanners from Mustek.
ManufacturerModelInterfaceStatusComment http://www.mustek.com/Mustek ScanExpress 6000 P Parport (EPP) good 300 dpi CCD scanner ScanExpress 600 SEP Parport (EPP) good 300 dpi CCD scanner ScanMagic 4800 P Parport (EPP) good 300 dpi CCD scanner 600 III EP Plus Parport (EPP) good 300 dpi CCD scanner 96 CP Parport (EPP) good 300x600 dpi CIS scanner ScanExpress 600 CP Parport (EPP) good 300x600 dpi CIS scanner ScanMagic 600 CP Parport (EPP) good 300x600 dpi CIS scanner ScanExpress 1200 CP Parport (EPP) good 600x1200 dpi CIS scanner ScanExpress 1200 CP+ Parport (EPP) good 600x1200 dpi CIS scanner http://www.medion.de/Medion/Lifetec/Tevion/Cytron MD 9848 Parport (EPP) good 300 dpi CCD scanner MD 9806 Parport (EPP) good 300 dpi CCD scanner MD/LT 935x Parport (EPP) good 600x1200 dpi CIS scanner MD/LT 985x Parport (EPP) good 600x1200 dpi CIS scanner MD/LT 9890 Parport (EPP) good 600x1200 dpi CIS scanner Targa
Funline TS12 EP Parport (EPP) good 600x1200 dpi CIS scanner Funline TS6 EP Parport (EPP) good 300x600 dpi CIS scanner http://www.trust-site.com/home/Trust Easy Connect 9600+ Parport (EPP) good 300x600 dpi CIS scanner Easy Connect 19200+ Parport (EPP) good 300x600 dpi CIS scanner Viviscan
Compact II Parport (EPP) good 300 dpi CCD scanner Cybercom
9352 Parport (EPP) good 300 dpi CCD scanner Gallery
4800 Parport (EPP) good 300 dpi CCD scanner Network
Easy Plus 30 Bit Parport (EPP) good 300 dpi CCD scanner Backend: mustek_usb
(1.0-18)
Link(s): 
http://www.meier-geinitz.de/sane/mustek_usb-backend/http://www.meier-geinitz.de/sane/mustek_usb-backend/ Manual page: http://www.sane-project.org/man/sane-mustek_usb.5.htmlsane-mustek_usb Comment: Only the USB scanners mentioned below are supported. For BearPaws, look at the Plustek, MA-1509, and gt68xx backends.
ManufacturerModelInterfaceStatusComment http://www.mustek.com/Mustek ScanExpress 600 CU USB complete  ScanExpress 1200 CU USB complete  ScanExpress 1200 CU Plus USB complete  ScanExpress 1200 UB USB complete For the UB Plus, see gt68xx backend http://www.trust-site.comTrust Compact Scan USB 19200 USB complete Mustek 1200 UB compatible Backend: mustek_usb2
(1.0-10, 
NEW!)
Link(s): 
http://www.meier-geinitz.de/sane/mustek_usb2-backend/http://www.meier-geinitz.de/sane/mustek_usb2-backend/ Manual page: http://www.sane-project.org/man/sane-mustek_usb2.5.htmlsane-mustek_usb2 Comment: Only BearPaw 2448TA Pro is supported at the moment
ManufacturerModelInterfaceStatusComment http://www.mustek.com/Mustek BearPaw 2448TA Pro USB good  Backend: nec
(0.12)
Link(s): 
http://www5a.biglobe.ne.jp/~saetaka/http://www5a.biglobe.ne.jp/~saetaka/ Manual page: http://www.sane-project.org/man/sane-nec.5.htmlsane-nec 
ManufacturerModelInterfaceStatusComment http://www.nevt.co.jp/NEC PC-IN500/4C SCSI good PC-IN500/4C was sold only in JAPAN Backend: niash
(0.2)
Link(s): 
http://sourceforge.net/projects/hp3300backendhttp://sourceforge.net/projects/hp3300backend Manual page: http://www.sane-project.org/man/sane-niash.5.htmlsane-niash 
ManufacturerModelInterfaceStatusComment http://www.hp.comHewlett-Packard ScanJet 3300c USB complete  ScanJet 3400c USB complete If you use Linux 2.6, version 2.6.8 or newer is necessary. ScanJet 4300c USB complete If you use Linux 2.6, version 2.6.8 or newer is necessary. http://www.agfa.comAgfa Snapscan Touch USB complete  Backend: pie
(1.0)
Link(s): 
http://www.munton.demon.co.uk/sanehttp://www.munton.demon.co.uk/sane Manual page: http://www.sane-project.org/man/sane-pie.5.htmlsane-pie 
ManufacturerModelInterfaceStatusComment http://www.blackwidow.co.uk/Devcom 9636PRO SCSI good  9636S SCSI untested  9630S SCSI untested  http://www.scanace.com/PIE ScanAce 1236S SCSI good  ScanAce 1230S SCSI good  ScanAce II SCSI untested  ScanAce III SCSI good  ScanAce Plus SCSI untested  ScanAce II Plus SCSI untested  ScanAce III Plus SCSI untested  ScanAce V SCSI untested  ScanAce ScanMedia SCSI untested  ScanAce ScanMedia II SCSI untested  ScanAce 630S SCSI untested  ScanAce 636S SCSI untested  Adlib
JetScan630 SCSI good  JetScan636PRO SCSI untested  Backend: plustek
(0.50)
Link(s): 
http://www.gjaeger.de/scanner/plustek/http://www.gjaeger.de/scanner/plustek/ Manual page: http://www.sane-project.org/man/sane-plustek.5.htmlsane-plustek 
ManufacturerModelInterfaceStatusComment http://www.plustek.de/Plustek OpticPro U12 USB complete NOTE: Devices with product ID 0x0001 are not supported! OpticPro UT12 USB complete Note: Devices with product ID 0x0001 are not supported! OpticPro UT16 USB complete  OpticPro U24 USB complete  OpticPro UT24 USB complete  http://www.geniusnet.com.tw/Genius Colorpage HR6 V2 USB complete  Colorpage HR7 USB complete  Colorpage HR6A USB untested  Colorpage HR7LE USB untested  Colorpage HR6X USB untested  http://www.mustek.com/Mustek BearPaw 1200 USB complete both product versions are supported, see backends' man-page BearPaw 2400 USB complete  http://www.hp.com/Hewlett-Packard ScanJet 2100C USB complete  ScanJet 2200C USB complete  http://www.epson.com/Epson Perfection 1250 USB complete  Perfection 1250Photo USB good TPA scans not perfect Perfection 1260 USB complete  Perfection 1260Photo USB good TPA scans not perfect http://www.umax.com/Umax UMAX 3400 USB complete there are some UMAX 3400 outside the U.S. which are not supported, as they use another chipset than the LM983x UMAX Astranet ia101 USB complete seems to be a renamed UMAX 3400 UMAX 3450 USB complete  UMAX 5400 USB complete  http://www.compaq.com/Compaq S4-100 USB complete Identical to UMAX 3400 http://www.canon.com/Canon CanoScan N650U/N656U USB complete  CanoScan N1220U USB complete  CanoScan N670U/N676U USB complete  CanoScan N1240U USB complete  CanoScan LiDE20 USB complete  CanoScan LiDE25 USB good  CanoScan LiDE30 USB complete  CanoScan D660U USB good TPA scans not perfect Backend: plustek_pp
(0.43)
Link(s): 
http://www.gjaeger.de/scanner/plustek_pp/http://www.gjaeger.de/scanner/plustek_pp/ Manual page: http://www.sane-project.org/man/sane-plustek_pp.5.htmlsane-plustek_pp 
ManufacturerModelInterfaceStatusComment http://www.plustek.de/Plustek OpticPro 4800P Parport (SPP, EPP) complete  OpticPro 4830P Parport (SPP, EPP) complete  OpticPro 600P/6000P Parport (SPP, EPP) complete  OpticPro 4831P Parport (SPP, EPP) complete  OpticPro 9630P Parport (SPP, EPP) complete  OpticPro 9630PL Parport (SPP, EPP) complete use driver-switch mov=1 OpticPro 9600P Parport (SPP, EPP) complete  OpticPro 1236P Parport (SPP, EPP) complete reported as OpticPro 12000P/96000P OpticPro 12000P/96000P Parport (SPP, EPP) complete  OpticPro 9636P Parport (SPP, EPP) complete use driver-switch mov=4 OpticPro 9636P+/Turbo Parport (SPP, EPP) complete use driver-switch mov=3 OpticPro 9636T Parport (SPP, EPP) complete  OpticPro 12000T Parport (SPP, EPP) complete  OpticPro AI3 Parport (SPP, EPP) basic use driver-switch mov=5, poor picture quality OpticPro P8 Parport untested  OpticPro P12 Parport (SPP, EPP) complete  OpticPro PT12 Parport (SPP, EPP) complete  http://www.primax.nl/Primax Colorado 4800 Parport (SPP, EPP) untested same as OpticPro 4800P Compact 4800 Direct Parport (SPP, EPP) complete use driver-switch mov=2 Compact 4800 Direct-30 Parport (SPP, EPP) complete same as OpticPro 4830P, use driver-switch mov=7 Compact 9600 Direct-30 Parport (SPP, EPP) complete same as OpticPro 9630P http://www.geniusnet.com.tw/Genius Colorpage Vivid III V2 Parport (SPP, EPP) complete Reported as PT12 Colorpage Vivid Pro II Film Parport (SPP, EPP) complete Reported as OP9636T/12000T Colorpage HR6X EPP Parport (SPP, EPP) good Negative scanning does not work correctly Aries
Scan-It Pro 4800 Parport (SPP, EPP) complete use driver-switch mov=2 BrightScan
BrighScan OpticPro Parport (SPP, EPP) complete Reported as P12 Backend: ricoh
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-ricoh.5.htmlsane-ricoh 
ManufacturerModelInterfaceStatusComment http://www.ricoh.com/Ricoh Ricoh IS50 SCSI basic  Ricoh IS60 SCSI basic  Backend: s9036
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-s9036.5.htmlsane-s9036 
ManufacturerModelInterfaceStatusComment http://www.siemens.com/Siemens 9036 Flatbed scanner SCSI basic  Backend: sceptre
(1.0-10)
Link(s): 
http://www.zago.net/sane/http://www.zago.net/sane/ Manual page: http://www.sane-project.org/man/sane-sceptre.5.htmlsane-sceptre 
ManufacturerModelInterfaceStatusComment http://www.sceptre.com/Sceptre Vividscan S1200 SCSI basic  http://www.komodo.com/Komodo S1200 SCSI untested rebadged Sceptre S1200 Backend: sharp
(0.32)
Link(s): 
http://www.satzbau-gmbh.de/staff/abel/sane-sharp.htmlhttp://www.satzbau-gmbh.de/staff/abel/sane-sharp.html Manual page: http://www.sane-project.org/man/sane-sharp.5.htmlsane-sharp 
ManufacturerModelInterfaceStatusComment http://sharp-world.com/Sharp JX-610 SCSI good  JX-250 SCSI good  JX-320 SCSI good  JX-325 SCSI untested  JX-330 SCSI good  JX-350 SCSI good  Backend: sm3600
(0.1)
Link(s): 
http://sm3600.sourceforge.net/http://sm3600.sourceforge.net/ Manual page: http://www.sane-project.org/man/sane-sm3600.5.htmlsane-sm3600 
ManufacturerModelInterfaceStatusComment http://www.microtek.com/Microtek ScanMaker 3600 USB basic works ScanMaker 3700 USB basic works ScanMaker 3750 USB basic works (told) Backend: sm3840
(1.1)
Link(s): 
http://www.ziplabel.com/sm3840/http://www.ziplabel.com/sm3840/ Manual page: http://www.sane-project.org/man/sane-sm3840.5.htmlsane-sm3840 Comment: This reverse-engineered backend supports the USB ScanMaker 3840 model
ManufacturerModelInterfaceStatusComment http://www.microtek.com/Microtek ScanMaker 3840 USB good 8 and 16 bit, color and grayscale ScanMaker 4800 USB good Same hardware as SM3840, different color box Backend: SnapScan
(1.4)
Link(s): 
http://snapscan.sourceforge.net/http://snapscan.sourceforge.net/ Manual page: http://www.sane-project.org/man/sane-snapscan.5.htmlsane-snapscan Comment: Supported  bit depths: 24 bit (color), 48 bit (color, Epson) 8 bit (gray)
ManufacturerModelInterfaceStatusComment http://www.agfa.com/AGFA SnapScan SCSI good  SnapScan 300 SCSI good  SnapScan 310 SCSI good  SnapScan 600 SCSI good Optional ADF supported. Arcus 1200 SCSI good Optional transparency unit supported. SnapScan 1236s SCSI good Optional ADF and transparency unit supported. SnapScan 1236u USB good Optional ADF and transparency unit supported. SnapScan 1212u USB good  SnapScan e10 USB good  SnapScan e20 USB good  SnapScan e25 USB good  SnapScan e26 USB good  SnapScan e40 USB good  SnapScan e42 USB good  SnapScan e50 USB good Optional tranparency unit supported SnapScan e52 USB good Optional tranparency unit supported SnapScan e60 USB untested  http://www.benq.comBenq (Acer) 300f SCSI good  310s SCSI good  610s SCSI good  610plus SCSI good  620s SCSI good  310u USB good  320u USB good  340u USB good  620u USB good Optional tranparency unit supported 640u USB good Optional tranparency unit supported 640bu USB good  640BT USB good Optional tranparency unit supported 1240 USB good Optional tranparency unit supported 3300 USB good  4300 USB good  5000E USB basic USB ID 0x04a5,0x20fc: Same as 5000U, working up to 600 DPI 5000U USB basic USB ID 0x04a5,0x20fc: Same as 5000E, working up to 600 DPI 5000 USB good USB ID 0x04a5,0x20f8: Color / grayscale scans working up to 1200 DPI 5300 USB basic Problems with firmware upload reported http://www.guillemot.comGuillemot / Hercules Maxi Scan A4 Deluxe (SCSI) SCSI good Rebadged SnapScan 310s. Scan@home Touch 1248 (USB) USB good Rebadged Benq 3300. Maxi Scan A4 USB 640U USB good Rebadged Benq 640U. Maxi A4 36 bit USB good Rebadged Benq 620U, needs Benq firmware file u96v???.bin http://www.mitsubishi.comMitsubishi Diamondview 648UT USB good Rebadged Benq 320u. Diamondview 650U USB good Rebadged Benq 4300. http://www.epson.comEpson Perfection 660 USB good  Perfection 1270 USB good  Perfection 1670 USB good  Perfection 2480 USB good  Perfection 2580 USB basic Film scanning unit unsupported Perfection 3490 USB good  Perfection 3590 USB basic Film scanning unit unsupported Backend: sp15c
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-sp15c.5.htmlsane-sp15c 
ManufacturerModelInterfaceStatusComment http://www.fcpa.fujitsu.com/products/scanners/Fujitsu ScanPartner 15C SCSI good  ScanPartner 600C SCSI good  Backend: st400
(1.6)
Link(s): 
http://www.informatik.uni-oldenburg.de/~ingo/sane/http://www.informatik.uni-oldenburg.de/~ingo/sane/ Manual page: http://www.sane-project.org/man/sane-st400.5.htmlsane-st400 
ManufacturerModelInterfaceStatusComment http://www.siemens.de/Siemens ST400 SCSI basic 6 bit gray ST800 SCSI basic 6 bit gray Backend: tamarack
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-tamarack.5.htmlsane-tamarack 
ManufacturerModelInterfaceStatusComment Tamarack
Artiscan 6000C SCSI good 3 pass, 300 DPI Artiscan 8000C SCSI good 3 pass, 400 DPI Artiscan 12000C SCSI good 3 pass, 600 DPI Backend: teco1
(1.0-10)
Link(s): 
http://www.zago.net/sane/#tecohttp://www.zago.net/sane/#teco Manual page: http://www.sane-project.org/man/sane-teco1.5.htmlsane-teco1 
ManufacturerModelInterfaceStatusComment http://www.relisys.com/Relisys RELI 2412 SCSI complete sub model VM3530+ AVEC 2400 SCSI complete sub model VM3520 RELI 4830 SCSI good sub model VM4542 AVEC 2412 SCSI complete sub model VM3520+ AVEC 4800 SCSI untested sub model VM4530 AVEC 4816 SCSI untested sub model VM4530+ RELI DS6 SCSI untested sub model VM3420 RELI DS15 SCSI untested sub model VM3440 RELI 2400 SCSI untested sub model VM3530 RELI 4816 SCSI complete sub model VM4540 RELI 9600 SCSI untested sub model VM6530 RELI 9612 SCSI untested sub model VM6530* RELI 9624 SCSI untested sub model VM6530+ RELI 9630 SCSI untested sub model VM6540 Actown
ACT Scan I 30 SCSI untested sub model VM3520A Dextra
DF-600P SCSI good sub model VM3510 DF-1200T+ SCSI untested sub model VM3530+ DF-4830T SCSI untested sub model VM4542 DF-9624 SCSI untested sub model VM6530+ Backend: teco2
(1.0-9)
Link(s): 
http://gkall.hobby.nl/teco2.htmlhttp://gkall.hobby.nl/teco2.html Manual page: http://www.sane-project.org/man/sane-teco2.5.htmlsane-teco2 
ManufacturerModelInterfaceStatusComment http://www.relisys.com/Relisys AVEC Super 3 SCSI untested sub model VM3575 AVEC II S3 SCSI good sub model VM3564 SCORPIO Super 3 SCSI good sub model VM3575 APOLLO Express 3 SCSI basic sub model VM356A APOLLO Express 6 SCSI good sub model VM6565 SCORPIO Pro SCSI good sub model VM6575 SCORPIO Pro-S SCSI untested sub model VM6586 http://www.primax.nl/Primax Jewel 4800 SCSI good sub model VM356A Profi 9600 SCSI basic sub model VM6575 Profi 19200 SCSI good sub model VM6586 http://www.mustek.com/Mustek ScanMagic 4830S SCSI untested sub model VM3575 Backend: teco3
(1.0-1)
Link(s): 
http://www.zago.net/sane/#teco3http://www.zago.net/sane/#teco3 Manual page: http://www.sane-project.org/man/sane-teco3.5.htmlsane-teco3 
ManufacturerModelInterfaceStatusComment http://www.tecoimage.com.tw/Relisys Infinity Scorpio SCSI good sub model VM3552 Plustek
OpticPro 2400SP SCSI untested sub model VM3552 http://www.image-land.com/PIOTECH Splendeur 3024 SCSI good sub model VM3552 Trust
Imagery 2400 SP SCSI good sub model VM3552 Imagery 4800 SP+ SCSI good sub model VM3552 Imagery 9600 SP SCSI untested sub model VM3552 Backend: u12
(0.02)
Link(s): 
http://www.gjaeger.de/scanner/u12/http://www.gjaeger.de/scanner/u12/ Manual page: http://www.sane-project.org/man/sane-u12.5.htmlsane-u12 
ManufacturerModelInterfaceStatusComment http://www.plustek.de/Plustek OpticPro U12 USB basic Note: Only devices with product ID 0x0001 are supported! OpticPro UT12 USB basic Note: Only devices with product ID 0x0001 are supported! OpticPro 1212U USB basic  RevScan
RevScan Orange R48Ti USB basic Rebadged Plustek OpticPro UT12 http://www.geniusnet.com.tw/Genius ColorPage HR6 V1 USB basic  ColorPage Vivid III USB USB untested Note: Device has Plustek vendor and product ID (0x07b3/0x0001) Backend: umax
(1.0-41)
Link(s): 
http://www.rauch-domain.de/sane-umax/index.htmlhttp://www.rauch-domain.de/sane-umax/index.html Manual page: http://www.sane-project.org/man/sane-umax.5.htmlsane-umax 
ManufacturerModelInterfaceStatusComment http://www.umax.com/UMAX Vista S6 SCSI good OK Vista S6E SCSI good OK UMAX S-6E SCSI good OK UMAX S-6EG SCSI good OK Vista-S8 SCSI good OK Supervista S-12 SCSI good OK UMAX S-12 SCSI good OK UMAX S-12G SCSI good OK Astra 600S SCSI good OK Astra 610S SCSI good OK Astra 1200S SCSI good OK Astra 1220S SCSI good OK Astra 2100S SCSI good OK Astra 2200 (SU) SCSI good OK Astra 2200 (SU) USB good OK, needs USB control messages Astra 2400S SCSI good OK Astra 6400 IEEE-1394 unsupported will propably work one day Astra 6450 IEEE-1394 unsupported will propably work one day Astra MX3 SCSI good OK Astra MX3 USB good OK, needs USB control messages Mirage D-16L SCSI good OK Mirage II SCSI good OK Mirage IIse SCSI good OK PSD SCSI good OK PowerLook SCSI good OK, SCSI-ID=PS-2400X PL-II SCSI good OK PowerLook III SCSI good OK PowerLook 270 SCSI unsupported incompatible PowerLook 270plus SCSI unsupported incompatible PowerLook 1100 IEEE-1394 unsupported will propably work one day PowerLook 2000 SCSI good OK PowerLook 2100XL SCSI good OK PowerLook 3000 SCSI good OK Gemini D-16 SCSI good OK UMAX VT600 SCSI untested may work, please test and give feedback Vista-T630 SCSI good OK for some firmwareversions, on others only lineart OK UC 630 SCSI good Version 2.8 OK, others only lineart OK UG 630 SCSI good OK UG 80 SCSI good OK UC 840 SCSI good Version 1.6 OK, others only lineart OK UC 1200S SCSI untested may work, please test and give feedback UC 1200SE SCSI good Version 3.0 OK, others unknown UC 1260 SCSI good Version 1.6 OK, others unknown http://www.heidelberg.com/Linotype Hell Jade SCSI good OK, SCSI-ID=LinoHell Office Jade SCSI good OK, SCSI-ID=LinoHell JADE Jade2 SCSI good OK, SCSI-ID=LinoHell Office2 Saphir SCSI untested support disabled until tested - please contact author Saphir2 SCSI good OK, SCSI-ID=LinoHell SAPHIR2 Saphir3 SCSI good OK, SCSI-ID=LinoHell SAPHIR3 Saphir Ultra SCSI untested support disabled until tested - please contact author Saphir Ultra II SCSI good OK, SCSI-ID=Linotype SAPHIR4 Saphir HiRes SCSI untested support disabled until tested - please contact author Opal SCSI untested support disabled until tested - please contact author Opal2 SCSI good OK; SCSI-ID=LinoHell OPAL2 Opal Ultra SCSI untested support disabled until tested - please contact author Linoscan 1400 SCSI good OK, SCSI-ID=HDM LS4H1S http://www.vobis.de/Vobis Highscreen Scanboostar Premium SCSI good OK, SCSI-ID=LinoHell Office2 EDGE
KTX-9600US SCSI untested no feedback http://www.epson.com/Epson Perfection 600 SCSI good OK, SCSI-ID=EPSON Perfection600 Escom
Image Scanner 256 SCSI good OK, SCSI-ID=UMAX UG 80 Escort
Galleria 600 SCSI untested untested, SCSI-ID=ESCORT Galleria 600S Genius
ColorPage-HR5 (Pro) SCSI good OK, SCSI-ID=KYE ColorPage-HR5 http://www.nikon.com/Nikon AX-110 / Scantouch 110 SCSI untested may work, please test and give feedback AX-210 SCSI good OK http://www.nikon.com/TriGem PowerScanII SCSI good OK Backend: umax1220u
(unmaintained)
Link(s): 
http://sourceforge.net/projects/umax1220u-sanehttp://sourceforge.net/projects/umax1220u-sane Manual page: http://www.sane-project.org/man/sane-umax1220u.5.htmlsane-umax1220u 
ManufacturerModelInterfaceStatusComment http://www.umax.com/UMAX Astra 1220U USB good OK Astra 1600U USB minimal Is reported to be the same as the 2000U. Sort of scans, but colors all messed up. Astra 2000U USB minimal Sort of scans, but colors all messed up. /unsupported/umax-astra-2100u.htmlAstra 2100 U USB minimal Colours are distorted, there are vertical colour stripes, and the image is shadowed inches to its left. Backend: umax_pp
(1)
Link(s): 
http://umax1220p.sourceforge.net/http://umax1220p.sourceforge.net/ Manual page: http://www.sane-project.org/man/sane-umax_pp.5.htmlsane-umax_pp 
ManufacturerModelInterfaceStatusComment http://www.umax.com.tw/UMAX Astra 1220P Parport (EPP/ECP) good  Astra 2000P Parport (EPP/ECP) good  Astra 1600P Parport (EPP/ECP) good  Astra 600P Parport (SPP/ECP) unsupported untested, but should be close to 610P Astra 610P Parport (SPP/ECP) good  Hewlett-Packard
Scanjet 3200C Parport (EPP/ECP) good works (relabelled 1220P and 2000P) Backend: unsupported
(2005-12-18)
Link(s): 
/contrib.html/contrib.html Comment: The devices mentioned here are not supported by any SANE backend. However, there may be links to information about them or stand-alone programs.
ManufacturerModelInterfaceStatusComment Agfa
1212 P Parport unsupported Most probably unsupported. /unsupported/microtek-scanmaker-8700.htmlDuoScan f40 USB IEEE-1394 unsupported Unsupported. See link for details. DuoScan T2000XL SCSI unsupported Unsupported. Same as Microtek ArtixScan 2020? DuoScan T2500 SCSI IEEE-1384 unsupported Unsupported. Same as Microtek Artixscan 2500f Ambir
/unsupported/syscan-travelscan-460.htmlVisigo A4 USB unsupported Not supported. See link for details. http://www.artecusa.com/Artec/Ultima /unsupported/artec_1236usb.html1236 USB USB unsupported Unsupported. Vendor/product 0x05d8/0x4001. See link for details. AM12e+ Parport unsupported Unsupported. Chips found inside: AT015, AD9816JS. Maybe similar to SCSI version or as6e? /unsupported/artec_epluspro.htmlE+ Pro USB unsupported Not supported. Work is ongoing to support it by the artec_eplus48u backend. See link for details.. /unsupported/artec-ultima-2000-2.htmlUltima 2000 (0x4001) USB unsupported Same name, but different ids: vendor/product 0x05d8/0x4001 is not supported. The scanner with product id 0x4002 is supported by the gt68xx backend. Avigramm
/unsupported/trust-combiscan-19200.htmlMinidoc USB unsupported Not supported. See link for details. http://www.avision.com/Avision DS310F Parport unsupported Probably not supported. Scanner/printer/copier combination. iVina FB2400 USB unsupported Not supported. No chipset information available. Same as UMAX Astra 6700. /unsupported/umax-astra-4500.htmliVina 1600 USB unsupported GL646 based, to be added to genesys backend. Same as UMAX Astra 4500. /unsupported/umax-astra-4700.htmliVina FB1800 USB unsupported GL646/GL660 based. Same as UMAX Astra 4700. http://www.benq.comBenq (Acer) 310p Parport unsupported Unsupported. No details about the protocol known. 320p Parport unsupported Unsupported. No details about the protocol known. 610p Parport unsupported Unsupported. No details about the protocol known. 620p Parport unsupported Unsupported. No details about the protocol known. 620pt Parport unsupported Unsupported. No details about the protocol known. /unsupported/benq-640p.html640p Parport unsupported Unsupported. Someone is working to ge this scanner supported. See link for details. Boeder
/unsupported/trust-combiscan-19200.htmlSm@rtScan Office Parport USB unsupported Unsupported. See link for details. http://www.brother.com/Brother http://sourceforge.net/projects/brother-mfcMFC 4600 Parport unsupported The parport 200x400dpi grayscale version of this scanner is unsupported. Dmitri Katchalov did some investigations on this scanner. If you want to write a backend, contact him (see link). /unsupported/brother-mfc-7300.htmlMFC 7300c Parport USB unsupported  http://www.canon.com/Canon /unsupported/canon-3000.htmlCanoScan 3000 USB unsupported GL660+GL646 based. /unsupported/canon-3000.htmlCanoScan 3000ex USB unsupported GL660+GL646 based. /unsupported/canon-3000.htmlCanoScan 3000F USB unsupported GL660+GL646 based. /unsupported/canon-3200f.htmlCanoScan 3200F USB unsupported Unsupported. backend is beeing developped. See link. /unsupported/canon-4200f.htmlCanoScan 4200F USB unsupported Probably unsupported. See link. /unsupported/canon-5000f.htmlCanoScan 5000F USB unsupported Unsupported. See link for details. /unsupported/canon-5200f.htmlCanoScan 5200F USB unsupported Probably unsupported. See link for details. /unsupported/canon-8000f.htmlCanoScan 8000F USB unsupported Not supported. USB Vendor/product 0x04a9/0x220f. See link for more information. With transparency adapter. /unsupported/canon-8400f.htmlCanoScan 8400F USB unsupported GL841 based, to be added to genesys backend /unsupported/canon-9900f.htmlCanoScan 9900F USB unsupported Probably unsupported, similar to 8000F. Vendor/product 0x04a9/0x2210. 3200x6400 dpi USB2. With transparency adapter. /unsupported/canon-d646u.htmlCanoScan D646U USB unsupported Probably not supported. USB Vendor/product 0x04a9/0x220b. See link for more information and test program. /unsupported/canon-d646u.htmlCanoScan D646U ex USB unsupported Probably not supported. See D646. /unsupported/canon-d1250u2.htmlCanoScan D1250U2 USB unsupported Not supported. However, someone started working on this scanner and some information is available (see link). /unsupported/canon-d2400uf.htmlCanoScan D2400UF USB unsupported Not supported. See link. /unsupported/canon-fb620u.htmlCanoScan FB620U USB unsupported Probably not supported. Vendor/product 0x4a9/0x2202. Some information is available. http://sourceforge.net/projects/canonscanner/CanoScan FB1210U USB unsupported Not supported. Vendor/product 0x4a9/0x2205. However, a stand-alone program for FreeBSD is available. /unsupported/canon-lide-80.htmlCanoScan LiDE 80 USB unsupported GL841 based, to be added to genesys backend /unsupported/canon-canoscan-lide-500f.htmlCanoScan LiDE 500F USB unsupported GL841 based, to be added to genesys backend /unsupported/canon-dr2080c.htmlDR-2080C USB SCSI unsupported Probably not supported. Pass-trough (ADF) scanner. DR-3020C SCSI unsupported Not supported. High-speed pass-trough (ADF) scanner. DR-3060 SCSI unsupported Probably not supported. High-speed pass-trough (ADF) scanner. DR-3080C SCSI unsupported Probably not supported. High-speed pass-trough (ADF) color scanner. /unsupported/canon-dr6080.htmlDR-6080 USB SCSI unsupported Probably not supported. High-speed pass-trough (ADF) scanner. DR-9080C SCSI unsupported Probably not supported. High-speed pass-trough (ADF) color scanner. Similar to DR-6080C, but can scan in color. /unsupported/canon-fs4000.htmlFS4000 USB SCSI unsupported Not supported. USB Vendor/product 0x04a9/0x3042. See link for more details. /unsupported/canon-is-12.htmlIS 12 USB unsupported Probably not supported. Scanner cardridge for Canon inkjet printers. /unsupported/canon-is-22.htmlIS 22 Parport unsupported Probably not supported. Scanner cardridge for Canon inkjet printers. /unsupported/canon-is-32.htmlIS 32 USB unsupported Probably not supported. Scanner cardridge for Canon inkjet printers. /unsupported/canon-is-52.htmlIS 52 ? unsupported Probably not supported. Scanner cardridge for Canon inkjet printers. /unsupported/canon-pixma-mp110.htmlPIXMA MP110 USB unsupported Probably not supported. See link for details. /unsupported/canon-pixma-mp130.htmlPIXMA MP130 USB unsupported Probably not supported. See link for details. /unsupported/canon-pixma-mp150.htmlPIXMA MP150 USB unsupported Probably not supported. See link for details. /unsupported/canon-pixma-mp170.htmlPIXMA MP170 USB unsupported Probably not supported. See link for details. /unsupported/canon-pixma-mp750.htmlPIXMA MP750 USB unsupported Probably not supported. See link for details. /unsupported/canon-pixma-mp780.htmlPIXMA MP780 USB unsupported Probably not supported. See link for details. Chinon
/unsupported/chinon-ds3000.htmlDS-3000 Parport Serial Port unsupported Unsupported at the moment, but a backend is in preparation. See link. http://www.compaq.com/Compaq S200 USB unsupported Not supported. 2400x1200 dpi. Vendor=0x049f, Product=0x0021. One bulk-in, one bulk-out and one interrupt endpoint. Type-number: U0001-HB21, another type nr on the inside: 75100512-00 Compeye
/unsupported/trust-combiscan-19200.htmlSimplex 1236C Parport USB unsupported Unsupported. See link for details. http://www.cardscan.com/Corex /unsupported/corex-cardscan-500.htmlCardscan 500 USB unsupported Probably not supported. Businesscard reader. http://www.dell.com/Dell /unsupported/dell-a920.htmlA920 USB unsupported Probably not supported. See link for details. /unsupported/dell-a960.htmlA960 USB unsupported Probably not supported. See link for details. /unsupported/dell-922.html922 USB unsupported Probably not supported. See link for details. /unsupported/dell-1600n.html1600n USB Ethernet unsupported Probably not supported. See link for details. http://www.epson.com/Epson GT-F600 USB unsupported Unsupported. Doesn't speak ESC/I. Closely related to the GT-9400. It will be supported by epkowa backeend in future. Perfection 4490 Photo USB unsupported Unsupported. Support is planned for the epkowa backend. USB vendor/product ID info: 0x04b8/0x0119 E-Lux
j-6121 Parport unsupported Probably unsupported. Sold 1998. Same as E-Lux j-6121. Enhans
j-6121 Parport unsupported Probably unsupported. Sold 1998. Same as E-Lux j-6121. M-3630 A Parport unsupported Probably unsupported. http://www.fujitsu.ca/Fujitsu fi-4010C USB unsupported Unsupported. Vendor/product: 0x04c5, 0x1029. Maybe similar to fi-4220C? fi-4110CU USB unsupported Unsupported. Vendor/product unknown. Maybe similar to fi-4220C? http://www.geniusnet.com.tw/Genius /unsupported/genius-colorpage-slim-1200.htmlColorPage Slim 1200 USB unsupported Unsupported. See link for details. /unsupported/genius-colorpage-slim-1200-usb2.htmlColorPage-Slim 1200 USB2 USB unsupported GL841 based, to be added to genesys backend. /unsupported/genius-colorpage-hr6x.htmlColorPage HR6X Slim USB unsupported GL646 based, to be added to genesys backend /unsupported/genius-colorpage-hr7x.htmlColorPage HR7X USB unsupported GL646 based, to be added to genesys backend /unsupported/genius-colorpage-hr8.htmlColorPage HR8 USB unsupported GL841 based, to be added to genesys backend /unsupported/genius-colorpage-sf600.htmlColorPage-SF600 USB unsupported Unsupported. See link for details. Guillemot
/unsupported/teco-vm6509.htmlSCAN@HOME 48 USB USB unsupported Probably unsupported. See link for details. Maxi Scan A4 Parallel 36 bit Parport unsupported Probably unsupported. Identical to the Benq Prisa 620P. Hercules
/unsupported/teco-vm6509.htmlSCAN@HOME 48 USB USB unsupported Probably unsupported. See link for details. http://www.hp.com/Hewlett-Packard /unsupported/hp-photo-1000.htmlPhoto Scanner 1000 USB unsupported Not supported by SANE. However, it's detected as mass storage device so just mounting it is reported to work. See link for devices data. Photosmart 1200 Photo USB unsupported Probably not supported by SANE. No details known. 10x15 cm. Maybe similar to Photo Scanner 1000? /unsupported/hp-photosmart-s20xi.htmlPhotosmart S20 (C5101A) USB unsupported Not supported yet by SANE, but a backend is under development. See link for details. /unsupported/hp-photosmart-s20xi.htmlPhotosmart S20xi (C7150A) USB unsupported Not supported yet by SANE, but a backend is under development. See link for details. /unsupported/hp-scanjet-2400c.htmlScanJet 2400c USB unsupported GL646 based, to be added to genesys backend /unsupported/hp-scanjet-3670c.htmlScanJet 3670c USB unsupported GL646 based, to be added to genesys backend /unsupported/hp-scanjet-3690.htmlScanJet 3690c USB unsupported Probably GL646_HP based, maybe can be added to genesys backend /unsupported/hp-scanjet-3800.htmlScanJet 3800c USB unsupported Probably unsupported, see link for details. /unsupported/hp-scanjet-3970c.htmlScanJet 3970c USB unsupported Unsupported. See link for details. /unsupported/hp-scanjet-4070.htmlScanJet 4070 Photosmart USB unsupported Unsupported. See link for details. /unsupported/hp-scanjet-4370.htmlScanJet 4370 USB unsupported Unsupported. See link for details. /unsupported/hp-scanjet-4500c.htmlScanJet 4500C USB unsupported Maybe GL841_HP, but not confirmed, maybe can be added to genesys backend /unsupported/hp-scanjet-4570c.htmlScanJet 4570C USB unsupported Maybe GL841_HP, but not confirmed, maybe can be added to genesys backend /unsupported/hp-scanjet-4600.htmlScanJet 4600 USB unsupported Not supported. See link for details. /unsupported/hp-scanjet-4600.htmlScanJet 4670 USB unsupported Not supported. See link for details. /unsupported/hp-scanjet-4850.htmlScanJet 4850C USB unsupported GL841, maybe can be added to genesys backend /unsupported/hp-scanjet-4850.htmlScanJet 4890C USB unsupported GL841, maybe can be added to genesys backend /unsupported/hp-scanjet-5500c.htmlScanJet 5500C USB unsupported Maybe GL841_HP, but not confirmed, maybe can be added to genesys backend /unsupported/hp-scanjet-5530.htmlScanJet 5530C Photosmart USB unsupported Maybe GL841_HP, but not confirmed, maybe can be added to genesys backend /unsupported/hp-scanjet-5550c.htmlScanJet 5550C USB unsupported Maybe GL841_HP, but not confirmed, maybe can be added to genesys backend /unsupported/hp-scanjet-5590.htmlScanJet 5590 USB unsupported Not supported. See link for details. /unsupported/hp-scanjet-7650.htmlScanJet 7650 USB unsupported Not supported. See link for details. http://www.ibm.comIBM ADF Color Scanner Proprietary unsupported Unsupported. Uses proprietary ISA card. Maybe the same as the Plustek Spectra ADF? http://www.iomagic.com/IOMagic /unsupported/trust-combiscan-19200.htmlMobileScan USB USB unsupported Unsupported. See link for details. http://www.kodak.comKodak /unsupported/kodak-i30.htmli30 USB unsupported Probably unsupported. See link for details. Snapshot Photo Scanner 1 Parport unsupported Unsupported. FCC ID HWF96PHS http://www.lexmark.com/Lexmark /unsupported/lexmark-p6250.htmlP6250 USB unsupported Unsupported. See link for details. /unsupported/lexmark-3150.htmlPhoto 3150 USB unsupported Unsupported. See link for details. /unsupported/lexmark-x75.htmlX74 USB unsupported Unsupported. See link for details. /unsupported/lexmark-x75.htmlX75 USB unsupported Unsupported. See link for details. /unsupported/lexmark-x75.htmlX75 PrinTrio USB unsupported Unsupported. See link for details. /unsupported/lexmark-x83.htmlX83 USB unsupported Unsupported. Vendor/product 0x043d/0x003d. GL640. /unsupported/lexmark-x5130.htmlX5130 USB unsupported Unsupported. /unsupported/lexmark-x5250.htmlX5250 USB unsupported Unsupported. /unsupported/lexmark-x6170.htmlX6170 USB unsupported Unsupported. See link for details. Logitech
PageScan Color Parport unsupported Most probably unsupported. /unsupported/logitech-pagescan-usb.htmlPageScan USB USB unsupported Probably unsupported. See link for details. http://www.medion.com/Medion/Lifetec/Tevion/Cytron /unsupported/medion-md6190.htmlMD 6190 USB unsupported Probably unsupported. There seem to exist two different scanners with that name. See link for details. /unsupported/tevion-md40420.htmlMD 40420 USB unsupported Probably unsupported. See link for details. /unsupported/medion-md6190.htmlMD 41260 USB unsupported Probably unsupported. See link for details. /unsupported/medion-md6190.htmlMD 41985 USB unsupported Probably unsupported. See link for details. /unsupported/tevion-md40420.htmlMD 42666 USB unsupported Probably unsupported. See link for details. /unsupported/tevion-md90009.htmlMD 90009 USB unsupported Probably unsupported. See link for details. /unsupported/tevion-md90070.htmlMD 90070 USB unsupported Probably unsupported. See link for details. http://www.memorex.com/Memorex /unsupported/memorex-maxx-6136u.html6136u USB unsupported Probably unsupported. /unsupported/visioneer-onetouch4400.html6142u USB unsupported Probably unsupported. Same as Visioneer Onetouch 4400. See link for details. /unsupported/trust-combiscan-19200.htmlMaxxScan 6122 USB Parport unsupported Unsupported. See link for details. /unsupported/memorex-scf-9612p.htmlSCF 9612P Parport unsupported Probably unsupported. See link for details. http://www.microtek.com/Microtek ArtixScan 2020 SCSI unsupported Unsupported. Same as Agfa DuoScan T2000XL? Artixscan 2500f SCSI IEEE-1384 unsupported Unsupported. Same as Agfa DuoScan T2500? ArtixScan 4000tf USB unsupported Unsupported. Uses ALI M5611B. /unsupported/microtek-filmscan-35.htmlFilmScan 35 USB	unsupported Probably unsupported. See link for details. ScanMaker 336 CX SCSI unsupported Probably unsupported. Seems to be similar to the Microtek 330 CX and is detected by the microtek2 backend. Scanning doesn't seem to work however. /unsupported/microtek-scanmaker-1850s.htmlScanmaker 1850S SCSI unsupported Unsupported. See link for details. /unsupported/microtek-scanmaker-3630.htmlScanMaker 3630 USB unsupported Unsupported. Doesn't seem to be compatible to 3600 series, see link. /unsupported/microtek-scanmaker-3800.htmlScanMaker 3800 USB unsupported Unsupported. See link for more details. /unsupported/microtek-scanmaker-3830.htmlScanMaker 3830 USB unsupported Unsupported. See link for more details. /unsupported/microtek-scanmaker-4700.htmlScanMaker 4700 USB unsupported Unsupported. See link for more details. /unsupported/microtek-scanmaker-4900.htmlScanMaker 4850 USB unsupported Probably unsupported. See link for details. /unsupported/microtek-scanmaker-4900.htmlScanMaker 4900 USB unsupported Unsupported. See link for more details. /unsupported/microtek-scanmaker-5600.htmlScanMaker 5 SCSI unsupported Probably unsupported. See link for more details. /unsupported/microtek-scanmaker-5600.htmlScanMaker 5600 USB unsupported Unsupported. See link for more details. ScanMaker 5700 USB unsupported Unsupported. Uses ALI M5615 like the ScanMaker 4700. /unsupported/microtek-scanmaker-5800.htmlScanMaker 5800 USB unsupported Unsupported. See link for details. /unsupported/microtek-scanmaker-5900.htmlScanMaker 5900 USB unsupported Unsupported. See link for more details. /unsupported/microtek-scanmaker-6000.htmlScanMaker 6000 USB unsupported Unsupported. See link for more details. /unsupported/microtek-scanmaker-6100.htmlScanMaker 6100 USB unsupported Unsupported. See link for more details. /unsupported/microtek-scanmaker-6700.htmlScanMaker 6700 USB IEEE-1394 unsupported Unsupported. See link. /unsupported/microtek-scanmaker-8700.htmlScanMaker 8700 USB IEEE-1394 unsupported Unsupported. See link for details. ScanMaker 9600XL USB IEEE-1394 unsupported Probably unsupported. SCSI seems to work with microtek2 backend. /unsupported/microtek-scanmaker-9800.htmlScanMaker 9800XL USB SCSI unsupported Partly unsupported. IEEE-1394 works with microtek2 backend. See link. /unsupported/microtek-scanmaker-i320.htmlScanMaker i320 USB unsupported Unsupported. See link. /unsupported/microtek-scanmaker-s400.htmlScanMaker s400 USB unsupported Unsupported. See link. /unsupported/microtek-scanport-3000.htmlScanPort 3000 USB unsupported Unsupported. Vendor/Product ids: 0x04a7/0x0224. Realtek RTS8801B?. See link for details. http://www.konicaminolta.com/Konica Minolta /unsupported/minolta-dual-scan-III.htmlDual Scan III USB unsupported Unsupported. May work with vuescan. See link for details. /unsupported/minolta-dual-scan-IV.htmlDual Scan IV USB unsupported Unsupported. Works with vuescan. See link for details. /unsupported/minolta-dse-5400.htmlDiMAGE Scan Elite 5400 USB IEEE-1394 unsupported Probably unsupported. May work with vuescan. See link for details. /unsupported/minolta-dse-5400-2.htmlDiMAGE Scan Elite 5400 2 USB unsupported Probably unsupported. See link for details. /unsupported/minolta-dimage-scan-multi-pro.htmlDiMAGE Scan Multi Pro IEEE-1394 unsupported Probably unsupported. See link for details. http://www.mustek.com/Mustek 1200 III EP Parport unsupported Probably not supported. quarlewm at jmu dot edu offers to temporarily loan such a scanner to anyone who is interested in writing a driver. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTED2400 M USB unsupported Probably unsupported. No details known. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTEDBearPaw 1248CU USB unsupported Probably unsupported. No details known. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTEDBearPaw 2400 TA Pro USB unsupported Not supported. May be supported by mustek_usb2 backend later. See link for some information. /unsupported/mustek-bearpaw-2448-cu-pro.htmlBearPaw 2448 CU Pro USB unsupported Not supported. May be supported by mustek_usb2 backend later. See link for some information. /unsupported/mustek-bearpaw-4800ta-pro.htmlBearPaw 4800 TA Pro USB unsupported Not supported. See link for some information. /unsupported/mustek-bearpaw-4800ta-pro-ii.htmlBearPaw 4800 TA Pro II USB unsupported Not supported.  May be supported by mustek_usb2 backend later. See link for some information. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTEDBearPaw 6400 TA Pro USB unsupported Not supported. May be supported by mustek_usb2 backend later. See link for some information. Paragon 800 II EP Parport unsupported Not supported. Maybe similar to 600 II EP (SCSI_over-parport)? In this case it could be supported by the mustek SCSI backend. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTEDScanExpress 600 USB USB unsupported Unsupported. Vendor/Product 0x055f/0x873. Programming information is available. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTEDScanExpress 1200 USB USB unsupported Unsupported. Vendor/Product 0x055f/0x0003. Programming information is available. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTEDScanExpress 1200 USB Plus USB unsupported Unsupported. Vendor/Product 0x055f/0x0007. http://penguin-breeder.org/?page=mustek_ppScanExpress 12000 P Parport unsupported Not supported. Asic 1505/05. ScanExpress A3 EP Parport unsupported Not supported. Maybe it will be supported by the mustek_pp backend in future. http://www.meier-geinitz.de/sane/misc/mustek-scanners.html#UNSUPPORTEDScanExpress CardSmart USB unsupported Probably unsupported. USB business card scanner. Maybe works as USB storage device? http://lists.alioth.debian.org/pipermail/sane-devel/2003-May/007682.htmlScanMagic 9636P Parport unsupported Probably not supported. Same as Mustek 12000 P?. ASIC 1505. http://www.nevt.co.jp/NEC /unsupported/nec-petiscan.htmlPetiscan USB unsupported Most probably unsupported. See link for details. Vendor ID is 0x0475 (Relisys/Teco). Not know if it is similar to other Relisys/Teco USB scanners. http://www.nikon.com/Nikon /unsupported/nikon-ls50-ed.htmlLS 50 ED USB unsupported Most probably unsupported. See link for details. /unsupported/nikon-ls50-ed.htmlCoolscan V ED USB unsupported Most probably unsupported. See link for details. /unsupported/nikon-ls5000-ed.htmlSuper Coolscan LS-5000 ED USB unsupported Most probably unsupported. See link for details. http://www.olivetti.comOlivetti /unsupported/olivetti-job-jet-m400.htmlJob-Jet M400 USB unsupported Probably not supported. See link for details. http://www.olympus.comOlympus /unsupported/olympus-es10s.htmlES-10S SCSI unsupported Probably not supported. See link for details. Optrox
http://www.df.lth.se/~triad/krad/optrox/PhotoMaker 3C Parport unsupported  http://www.df.lth.se/~triad/krad/optrox/PhotoMaker 3E Parport unsupported  http://www.df.lth.se/~triad/krad/optrox/PhotoMaker 3F Proprietary unsupported Special ISA card http://www.df.lth.se/~triad/krad/optrox/PhotoMaker 3S Parport unsupported  http://www.df.lth.se/~triad/krad/optrox/PhotoMaker 6E Parport unsupported  http://www.df.lth.se/~triad/krad/optrox/PhotoMaker 6F Proprietary unsupported Special ISA card Panasonic
KV-SS905C ? unsupported might be supported by matsushita backend. KV-S2026C ? unsupported might be supported by matsushita backend. KV-S2046C ? unsupported might be supported by matsushita backend. KV-S2055W ? unsupported might be supported by matsushita backend. KV-S2055L ? unsupported might be supported by matsushita backend. KV-S2065W ? unsupported might be supported by matsushita backend. KV-S3065CW ? unsupported might be supported by matsushita backend. KV-S3065CL ? unsupported might be supported by matsushita backend. KV-S3085 ? unsupported might be supported by matsushita backend. KV-S3105C ? unsupported might be supported by matsushita backend. KV-S6040W ? unsupported might be supported by matsushita backend. KV-S6045W ? unsupported might be supported by matsushita backend. KV-S6050W ? unsupported might be supported by matsushita backend. KV-S6055W ? unsupported might be supported by matsushita backend. KV-S7065C ? unsupported might be supported by matsushita backend. Pentax
/unsupported/syscan-travelscan-pro.htmlDSmobile USB USB unsupported Probably not supported. Some information is available. http://www.scanace.com/PIE /unsupported/pie-1800u.htmlPrimefilm 1800u USB unsupported Not supported. Vendor/product 0x05e3/0x0120. See link for details. Primefilm 3600PRO USB IEEE-1394 unsupported Probably not supported. /unsupported/reflecta-digitdia-3600.htmlPowerslide 3600 USB IEEE-1394 unsupported Probably unsupported. Film scanner that can scan directly from the magazine. http://www.plustek.de/Plustek /unsupported/plustek-opticbook-3600.htmlOpticBook 3600 USB unsupported GL842 based (similar to GL841?), maybe ca be added to genesys backend. Bookscanner. /unsupported/plustek-opticfilm-7200.htmlOpticFilm 7200 USB unsupported GL841 based, to be added to genesys backend OpticPro A3U USB unsupported Uses Plustek ASIC P99002 OpticPro S6 USB unsupported Uses RealTek chipset (RTL8801D) /unsupported/plustek-opticpro-st12.htmlOpticPro S12 USB unsupported  /unsupported/plustek-opticpro-st12.htmlOpticPro ST12 USB unsupported  /unsupported/plustek-opticpro-st16.htmlOpticPro ST16 USB unsupported GL646 based, to be added to genesys backend OpticPro UA18 USB unsupported Probably LM983x based. /unsupported/plustek-opticpro-st24.htmlOpticPro S24 USB unsupported GL646 based, to be added to genesys backend /unsupported/plustek-opticpro-st24.htmlOpticPro ST24 USB unsupported GL646 based, to be added to genesys backend /unsupported/plustek-opticpro-s28.htmlOpticPro S28 USB unsupported GL841 based, to be added to genesys backend /unsupported/plustek-opticpro-s28.htmlOpticPro ST28 USB unsupported GL841 based, to be added to genesys backend /unsupported/plustek-opticpro-st48.htmlOpticPro ST48 USB unsupported GL841 based, to be added to genesys backend OpticPro ST64 USB unsupported No further information available. /unsupported/plustek-opticslim-2420.htmlOpticSlim 2420 USB unsupported GL841 based, to be added to genesys backend OpticWorks 2000 Parport unsupported Multifunction device. No further information available. OptiCard 600+ USB unsupported Business card reader. No further information available. Spectra ADF Proprietary unsupported Unsupported. Uses proprietary ISA card that also provides power and is labelled GPS-1 PAGE-A from Taiwan. Other labels on the scanner include ADF Color Scanner and SF600AS. Maybe the same as the IBM ADF Color Scanner? http://www.primax.nl/Primax /unsupported/primax-colorado-600u.htmlColorado 600U USB unsupported Not supported. Some information is available. http://home2.swipnet.se/~w-25069/pxscan.htmlColorado 1200p Parport unsupported Unsupported by SANE. But is reported to partly work with pxscan. See link. /unsupported/visioneer-onetouch4400.htmlPrimascan Colorado 2600u USB unsupported Unsupported. Same as Visioneer Onetouch 4400. See link for details. http://home2.swipnet.se/~w-25069/pxscan.htmlColorado Direct 600 Parport unsupported Not supported. However, a stand-alone program is available. http://home2.swipnet.se/~w-25069/pxscan.htmlColorado Direct 9600 Parport unsupported Not supported. However, a stand-alone program is available. /unsupported/primax-colorado-usb-9600.htmlColorado USB 9600 USB unsupported Not supported. See link for details. OneTouch 5300 Parport unsupported Not supported. /unsupported/medion-md6228.htmlSlim-Line 1200 USB unsupported Maybe GL646. http://www.fida.com/Prolink /unsupported/prolink-2448u.htmlWinscan Pro 2448U USB unsupported Not supported. Some information is available. Vendor=0x06dc product=0x0014. RealTek RTS8801. http://www.quato.de/Quato X-Finity SCSI unsupported Probably not supported. No details yet. Originally manufactured by PFU? X-Finity Ultra USB IEEE-1394 unsupported Probably not supported. No details yet. Reflecta
/unsupported/reflecta-digitdia-3600.htmlDigitDia 3600 USB IEEE-1394 unsupported Film scanner that can scan directly from the magazine. /unsupported/reflecta-iscan-1800.htmliScan 1800 USB unsupported Probably unsupported. See link for details. /unsupported/reflecta-proscan-4000.htmlProScan 4000 USB IEEE-1394 unsupported Probably unsupported. See link for details. Relisys
/unsupported/relisys-eclipse-1200u.htmlEclipse 1200U USB unsupported Probably unsupported. See link for details. /unsupported/relisys-scorpio-ultra3.htmlScorpio Ultra 3 USB unsupported Probably unsupported. See link for details. /unsupported/relisys-episode.htmlEpisode USB unsupported Probably unsupported. See link for details. Sicos
mailto:ehaase@inf.fu-berlin.deDMS 2000 proprietary unsupported Not supported until now. Work on a backend has started, contact the author for details (see link) SmartScan 3600 USB IEEE-1394 unsupported Probably not supported. Same as PIE Primefilm 2600 PRO. Spot Technology
http://www.el-profesor.net/spoonset/Maxiscan A4 proprietary unsupported Not supported until now. Work on a backend has started, see link for more information. http://www.el-profesor.net/spoonsetScanTak 2c proprietary unsupported Not supported. Work on a backend has started, see link for more information. http://www.el-profesor.net/spoonsetScanTak 3c proprietary unsupported Not supported. Work on a backend has started, see link for more information. Syscan
/unsupported/syscan-travelscan-460.htmlTravelScan 460/464 USB unsupported Not supported. Some information is available. See link for details. /unsupported/syscan-travelscan-fs531.htmlTravelScan FS-531 USB unsupported Not supported. May work with the Plustek backend in future. See link for details. /unsupported/syscan-travelscan-pro.htmlTravelScan Pro USB unsupported Probably not supported. Some information is available. Tamarack
http://www.autistici.org/tamarhack/Artiscan 9600 Parport unsupported Unsupported at the moment. See link for a project for that scanner taht may support it in future. http://www.autistici.org/tamarhack/Artiscan 9600 pro 36 Parport unsupported Unsupported at the moment. See link for a project for that scanner. http://www.tce.com.br/TCE /unsupported/memorex-maxx-6136u.htmlMK600U USB unsupported Not supported. Some information is available. http://home2.swipnet.se/~w-25069/pxscan.htmlS450 Parport unsupported Not supported by SANE but is reported to work with pxscan (see link). http://www.tecoimage.com.tw/Teco /unsupported/teco-vm6509.htmlVM6509F USB unsupported Probably unsupported. See link for details. Tiny
/unsupported/visioneer-onetouch4400.htmlFU661E USB unsupported Unsupported. See link for details. http://www.trust-site.comTrust /unsupported/trust-combiscan-19200.htmlCombiScan 19200 Parport USB unsupported Unsupported. See link for details. /unsupported/trust-scsi-scan-19200.htmlSCSI Scan 19200 -Excellence Series- SCSI unsupported Unsupported. See link for details. http://www.umax.com/UMAX /unsupported/umax-astra-2500.htmlAstra 2500 USB unsupported Probably not supported. See link for details. /unsupported/umax-astra-3000.htmlAstra 3000 USB unsupported Probably not supported. See link for details. /unsupported/umax-astra-3400.htmlAstra 3400 USB unsupported Model ID 0x0050 not supported. See link for details. /unsupported/umax-astra-3600.htmlAstra 3600 USB unsupported Probably not supported. See link for details. /unsupported/umax-astra-4000.htmlAstra 4000 USB unsupported Not supported. See link for details. /unsupported/umax-astra-4100.htmlAstra 4100 USB unsupported Not supported, to be added to genesys backend. /unsupported/umax-astra-4400.htmlAstra 4400 USB unsupported Probably not supported. See link for details. /unsupported/umax-astra-4450.htmlAstra 4450 USB unsupported Probably not supported. See link for details. /unsupported/umax-astra-4500.htmlAstra 4500 USB unsupported GL646 based, to be added to genesys backend. Avision iVina FB1600 clone Astra 4600 USB unsupported Probably not supported, no details known. /unsupported/umax-astra-4700.htmlAstra 4700 USB unsupported GL646/GL660 based. Avision iVina FB1800 clone. Astra 6700 USB unsupported Not supported. No chipset information available. Same as Avision iVina FB2400. /unsupported/umax-astraslim.htmlAstraSlim USB unsupported Probably not supported currently. See link for more details. /unsupported/umax-astraslim-6000.htmlAstraSlim 6000 USB unsupported Probably not supported currently. See link for more details. /unsupported/umax-powerlook-180.htmlPowerlook 180 USB unsupported Probably not supported. See link for details. Powerlook 1000 USB USB unsupported Probably not supported. No further information available. Vantas
/unsupported/visioneer-onetouch4800.html3000 USB unsupported Not supported. See link for more details. http://www.visioneer.com/Visioneer http://ingchai.sytes.net:81/scanner-info.txt6200 USB unsupported Not supported. Is reported to use the E5 chipset. Uses a Primax ID. See link for some details. Looks similar to Primascan Colorado 2600u. /unsupported/visioneer-onetouch4400.htmlOnetouch 4400 USB unsupported Not supported. E5 chipset? Vendor/product 0x0461/0x0347.See link for more details. /unsupported/visioneer-onetouch4800.htmlOneTouch 4800 USB USB unsupported Unsupported. Vendor/Product ids: 0x04a7/0x0224. Seems to use Realtek RTS8801B. Same as Microtek Scanport 3000. See link for details. /unsupported/visioneer-onetouch5300.htmlOneTouch 5300 USB USB unsupported Not supported. Vendor/product ids 0x04a7/0x0226. Chipset is RTS8801B(?). See link for output of /proc/bus/usb/devices. /unsupported/visioneer-onetouch5800.htmlOneTouch 5800 USB USB unsupported Unsupported. 48 bit scanner, doesn't work with viceo backend. RTS8801C. Vendor/product 0x04a7/0x0226. /unsupported/visioneer-onetouch6600.htmlOneTouch 6600 USB unsupported Unsupported. See link for details. /unsupported/visioneer-onetouch7100.htmlOnetouch 7100 USB unsupported GL646 based, to be added to genesys backend /unsupported/visioneer-onetouch8100.htmlOneTouch 8100 USB unsupported Unsupported. See link for details. /unsupported/visioneer-onetouch8920.htmlOnetouch 8700 USB unsupported Not supported. See link for details. Onetouch 8900 USB unsupported Not supported. Same as 8920 but without TA? /unsupported/visioneer-onetouch8920.htmlOnetouch 8920 USB unsupported Not supported. Same as 8700 and 8900 but includes a TA. Uses a Primax ID. Chipset is RTS8801C. See link for output of /proc/bus/usb/devices. /unsupported/visioneer-onetouch9020.htmlOnetouch 9000 USB unsupported Not supported. See link for details. /unsupported/visioneer-onetouch9020.htmlOnetouch 9020 USB unsupported Not supported. See link for details. /unsupported/visioneer-onetouch8820.htmlOnetouch Pro 8800 USB unsupported Probably not supported. See link for details. /unsupported/visioneer-onetouch8820.htmlOnetouch Pro 8820 USB unsupported Probably not supported. See link for details. /unsupported/visioneer-paperport-3100b.htmlPaperPort 3100b Parport unsupported Most probably not supported. See link for details. PaperPort 6100 Parport unsupported Most probably not supported. More details would be appreciated. /unsupported/visioneer-paperport-onetouch.htmlPaperPort OneTouch Parport unsupported Most probably not supported. See link for details. /unsupported/visioneer-onetouch4400.htmlPrimascan Colorado 2600u USB unsupported Not supported. See Visioneer Onetouch 4400. /unsupported/visioneer-strobe-xp-100.htmlStrobe XP 100 USB unsupported Not supported but may work in future. See link for details. http://www.xerox.com/Xerox /unsupported/xerox-2400-onetouch.html2400 Onetouch USB unsupported Probably GL646_HP based, maybe can be added to genesys backend /unsupported/xerox-docuimage-620s.htmlDocuImage 620S SCSI unsupported Not supported. See link for more details. /unsupported/xerox-workcentre-470cx.htmlWorkCentre 470cx Parport unsupported Not supported. See link for more details. /unsupported/xerox-workcentre-m15i.htmlWorkCentre M15i USB unsupported Not supported. See link for more details. /unsupported/xerox-workcentre-xk35c.htmlWorkCentre XK35c USB Parport unsupported Not supported. See link for more details. /unsupported/xerox-workcentre-xk50cx.htmlWorkCentre XK50cx USB unsupported Not supported. See link for more details. /unsupported/xerox-workcentre-pro412.htmlWorkCentre Pro 412 USB Parport unsupported Not supported. See link for more details. /unsupported/xerox-workcentre-pe16.htmlWorkCentre PE16 USB Parport unsupported Not supported. See link for more details. Still Cameras 
Backends: 
#C-DC25dc25 , 
#C-DC210dc210 , 
#C-DC240dc240 , 
#C-DMCdmc 
Backend: dc25
(1.2)
Link(s): 
mailto:peter@fales-lorenz.netmailto:peter@fales-lorenz.net Manual page: http://www.sane-project.org/man/sane-dc25.5.htmlsane-dc25 
ManufacturerModelInterfaceStatusComment http://www.kodak.com/global/en/service/digCam/dc25/dc25.shtmlKodak DC25 Serial port complete  DC20 Serial port basic DC-20 untested by author but reported to work Backend: dc210
(0.0)
Link(s): 
mailto:peter@fales-lorenz.netmailto:peter@fales-lorenz.net Manual page: http://www.sane-project.org/man/sane-dc210.5.htmlsane-dc210 
ManufacturerModelInterfaceStatusComment http://www.kodak.com/global/en/service/digCam/dc210/dc210.shtmlKodak DC210 Serial port basic  Backend: dc240
(0.0)
Link(s): 
mailto:peter@fales-lorenz.netmailto:peter@fales-lorenz.net Manual page: http://www.sane-project.org/man/sane-dc240.5.htmlsane-dc240 
ManufacturerModelInterfaceStatusComment http://www.kodak.com/global/en/service/products/ekn006568.jhtmlKodak DC240 Serial port good Use gphoto2 backend to get USB support Backend: dmc
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-dmc.5.htmlsane-dmc 
ManufacturerModelInterfaceStatusComment http://www.polaroid.com/Polaroid DMC SCSI good  Video Cameras 
Backends: 
#V-QCAMqcam , 
#V-UNSUPPORTEDunsupported 
Backend: qcam
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-qcam.5.htmlsane-qcam 
ManufacturerModelInterfaceStatusComment Connectix
Color QuickCam Parport good Requires root privileges. Greyscale QuickCam Parport minimal Requires root privileges.  Partly working. Backend: unsupported
(2005-12-18)
Link(s): 
/contrib.html/contrib.html Comment: The devices mentioned here are not supported by any SANE backend. However, there may be links to information about them or stand-alone programs.
ManufacturerModelInterfaceStatusComment Biolux
/unsupported/biolux-654.html654 (micrOcular) USB unsupported Not supported yet. See link for more details. Grandtek Scopecam
/unsupported/grandtech-scopecam.html8x30 Binocular & Digital Camera USB unsupported Not Supported yet. See link for more details. APIs 
Backends: 
#A-GPHOTO2gphoto2 , 
#A-PINTpint , 
#A-PNMpnm , 
#A-TESTtest , 
#A-V4Lv4l 
Backend: gphoto2
(0.0)
Link(s): 
mailto:peter@fales-lorenz.netmailto:peter@fales-lorenz.net Manual page: http://www.sane-project.org/man/sane-gphoto2.5.htmlsane-gphoto2 Description: http://www.gphoto.orgMultiple cameras supported by the gphoto2 libraries Comment: The long-term plan is to support all the cameras supported by the gphoto2 libraries (currently over 140 models).  However, at this stage, only a handful of cameras are definitely known to work with SANE.  Other cameras will probably work if the native file format is EXIF or JPEG.  Testers welcome!
Backend: pint
(unmaintained)
Manual page: http://www.sane-project.org/man/sane-pint.5.htmlsane-pint Description: Scanners with the machine-independent PINT interfaceComment: Haven't been tested for a long time. Handle with care.
Backend: pnm
(1.0.8)
Link(s): 
mailto:henning@meier-geinitz.demailto:henning@meier-geinitz.de Manual page: http://www.sane-project.org/man/sane-pnm.5.htmlsane-pnm Description: Reads PNM filesComment: Used for debugging frontends. Obsolete, use test backend instead.
Backend: test
(1.0-26)
Link(s): 
http://www.meier-geinitz.de/sane/test-backend/http://www.meier-geinitz.de/sane/test-backend/ Manual page: http://www.sane-project.org/man/sane-test.5.htmlsane-test Description: Frontend-testerComment: Backend for testing frontends. Also serves as example for SANE backend options.
Backend: v4l
(1.0-3)
Link(s): 
mailto:henning@meier-geinitz.demailto:henning@meier-geinitz.de Manual page: http://www.sane-project.org/man/sane-v4l.5.htmlsane-v4l Description: Interface to Video For Linux APIComment: Supports video cameras and other devices accessed by the v4l kernel API, e.g. bttv devices. Quite a lot of known bugs.
Meta Backends 
Backends: 
#M-DLLdll , 
#M-NETnet 
Backend: dll
(1.0.11)
Link(s): 
mailto:henning@meier-geinitz.demailto:henning@meier-geinitz.de Manual page: http://www.sane-project.org/man/sane-dll.5.htmlsane-dll Description: Dynamic loading of shared-library backends.
Backend: net
(1.0.13)
Link(s): 
http://www.penguin-breeder.org/?page=sane-nethttp://www.penguin-breeder.org/?page=sane-net Manual page: http://www.sane-project.org/man/sane-net.5.htmlsane-net Description: Network access to saned serversComment: Can be used to access any scanner supported by SANE over the net. Supports IPv4 and IPv6.
Legend: 
  
Backend:  
Name of the backend,  in parentheses if available:
      Version of backend/driver; newer versions may be
      available from their home sites.
      NEW! means brand-new to the
      current release of SANE.
      UNMAINTAINED means that nobody maintains that backend. Expect no 
      new features or newly supported devices. You are welcome to take over 
      maintainership.
  
  
Link(s):  
Link(s) to more extensive and
      detailed information, if it exists, or the email address
      of the author or maintainer.
  
Manual Page:  
A link to the man-page online, if it exists.  
Comment:  
More information about the backend or model, e.g. the level of       support and possible problems.  
Manufacturer:  
Manufacturer, vendor or brand name of the device.  
Model:  
Name of the the device.  
Interface:  
How the device is connected to the computer.  
Status:  
Indicates how many of the features the device provides 
      are supported by SANE.
      
unsupported        means the device is not supported at least by this backend.         It may be supported by other backends, however.
      
untested means the         device may be supported but couldn't be tested. Be very         careful and report success/failure.
      
minimal means that the
        device is detected and scans at least in one mode. But the quality 
        is bad or important features won't work.
      
basic means it works at 
        least in the most important modes but quality is not perfect.
      
good means the device is usable 
        for day-to-day work. Some rather exotic features may be missing.
      
complete means the backends 
        supports everything the device can do.
      
  
Description:  
The scope of application of the backend.
http://www.sane-project.org/SANE homepage http://www.sane-project.org/imprint.htmlContact This page was last updated on Tue May  2 09:27:41 2006
 